l a�aid C,a�lnntors/M IN, hICIWitNin <br />, <br />U CERTIFIED <br />5 " FABRICATOR <br />Q AND ERECTOR <br />1 <br />• (1) Ea 10' W X 12'H Cookson Insulated Service door, 22ga int/ext slats, chain hoist <br />• (2) Ea. 3070 walk doors <br />• Foundation — Spread footers beneath columns, 8 "W x 36" grade beam with pilasters at columns(30" below <br />grade with 6" above grade), 6" slab on grade, 4'x4' x 4" stoops at walk doors, 12'W x 20'L x 6" concrete <br />apron at overhead door. <br />• Electrical <br />o 200 amp 3 phase, 120/208 volt service, nema 1, with meter socket, service from Black Hills adja- <br />cent to building, grounding per code, breakers and circuits to supply the following. <br />• 2 -15KW electric unit heaters with stats <br />• 12- 6 -lamp P5 fixtures, 3 switches <br />• 2- outside wall -paks with photo -cell <br />• 10- receptacles, 1 mounted on outside wall, 2 per 20 amp circuit <br />• 2- ceiling fans to help push heat down with speed control switches <br />• The raceway system is EMT conduit with pressed metal boxes. <br />GENERAL QUALIFICATIONS: <br />• Engineering is included <br />• Building Permit included <br />• Any existing hazardous material abatement to be provided by others <br />• Electrical to within 5' of buildings to be provided by owner <br />• Quote based on straight time <br />• Quote assumes 1500psf soil bearing capacity <br />• Building Use and Occupancy Classification: ICM has assumed all products in storage will be closed con- <br />tainers, Class IIIB Combustible Liquids (Flash Point at or above 200 degrees F). Per table 307.1(1) of the <br />IBC the maximum allowable storage is 13,200 gallons. We are looking at less than 5,000 gallons, so the <br />lube storage building should not be classified as hazardous and does not require a fire suppression sys- <br />tem, explosion proof electrical, special ventilation or fire rated walls therefore any of these requirements <br />have not been included. <br />• Assuming structure that Lube storage is within 10' is not an occupied structure, special separation has not <br />been included. <br />• No dewatering <br />• No rock excavation <br />• No plumbing <br />• HVAC — Electric Unit Heaters Only, No ventilation or cooling <br />• Concrete testing is not included <br />• Site Preparation: ICM has assumed only minimal leveling of site may be required. <br />• Subgrade prep: ICM has assumed existing soil will be adequate therefore we are excluding any overexca- <br />vation and recompaction and excluding importing of any fill materials. ICM will excavate as required for <br />spread footings and grade beams and place on undisturbed soil. <br />• Final Grading — ICM has assumed there will be minimal grading around perimeter of buildings to ensure <br />drainage away from buildings. ICM assumes spoils will be adequate for final grading and if required CC &V <br />will truck soil to building sites. <br />• No Floor finishes <br />• Bonding is excluded <br />Page 2 of 3 <br />2013_026 CCV Pre - Engineered Metal Storage Buildings <br />