My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-03-14_REPORT - C1981010 (7)
DRMS
>
Day Forward
>
Report
>
Coal
>
C1981010
>
2013-03-14_REPORT - C1981010 (7)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:14:59 PM
Creation date
3/14/2013 10:49:32 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981010
IBM Index Class Name
REPORT
Doc Date
3/14/2013
Doc Name
2012 Annual Hydrology Report
From
Trapper Mining, Inc
To
DRMS
Annual Report Year
2012
Permit Index Doc Type
Hydrology Report
Email Name
JLE
SB1
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
673
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5.0 SURFACE -WATER QUALITY <br />Samples were collected from active sites 001, 002, 005, 011, 013, 014, 015, 017, 018, 020, <br />021 and S -1 during 2012. Analytical results for these surface water samples are presented in Table <br />C -1 (page C -29). The more frequently measured parameters are presented with the first series of <br />values. The less frequent measured parameters are in two separate groups and shown after the first <br />group of parameters in Table C -1. NPDES sites 008, 012, 016, 019, 022, 023 and 024 had no <br />discharge during 2012 and, therefore, no data are presented. <br />5.1 TSS <br />Figures C -5, C -7, C -9, C -11, C -13 and C -15 present plots of total suspended solids (TSS) <br />versus time for the sites 001, 002, 011, 017, 013, 018, 020, 021 and S -1. The 2012 TSS values were <br />small and similar to the low range of previously observed values except for the higher TSS values <br />with the large flow for NPDES site 021 (see Figure C -14). Figure C -9 shows that the 2012 values <br />were consistent with the past values for sites 011 and 017. S -1 TSS value was very small in 2012. <br />Plots of flow versus TSS for the same sites are presented in Figures C -6, C -8, C -10, C -12, C -14 and <br />C -16. As expected, a general increase in TSS for an increase in flow is seen in these plots for the <br />historical data from these sites with the 2012 data supporting the historical relationship between flow <br />and TSS. <br />5.2 CONDUCTIVITY <br />The conductivity versus time plot for site NPDES 001 shows a similar, but slightly higher, <br />range of conductivity in 1998 through 2012 to the range observed over the previous few years (Figure <br />Trapper Mining Company 5 -1 <br />2012 Annual Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.