ADZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Inorganic Extended <br />Qualifier Report <br />Golder Associates ACZ Project ID: L97854 <br />• <br />L97854 -01 WG334288 Sodium, dissolved M200 7 ICP BB Target analyte detected in calibration blank at or above <br />acceptance limit Sample value was > 10X the <br />concentration in the calibration blank <br />WG334551 Chloride M300 0 - Ion Chromatography DC Sample required dilution Non - target analyte exceeded <br />calibration range <br />M300 0 - Ion Chromatography RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334369 Fluoride SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334153 Nitrate /Nitrite as N, dissolved M353 2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Nitrite as N, dissolved M353 2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334202 pH SM4500H+ B ZW Method deviation The sample was centnfuged prior to <br />analysis due to high solid content <br />WG334204 Residue, Filterable (TDS) @180C SM2540C ZO Concentration is based on a final residue greater than 200 <br />mg <br />WG334202 Total Alkalinity SM2320B - Titration ZW Method deviation The sample was centrifuged prior to <br />analysis due to high solid content <br />L97854 -02 WG334551 Chloride M300 0 - Ion Chromatography RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334369 Fluoride SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334153 Nitrate /Nitrite as N, dissolved M353 2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Nitrite as N, dissolved M353 2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334204 Residue, Filterable (TDS) @180C SM2540C ZO Concentration is based on a final residue greater than 200 <br />mg <br />WG334551 Sulfate M300 0 - Ion Chromatography DC Sample required dilution Non - target analyte exceeded <br />calibration range <br />L97854 -03 WG335659 Chloride M300 0 - Ion Chromatography RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334369 Fluoride SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334153 Nitrate /Nitrite as N, dissolved M353 2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Nitrite as N, dissolved M353 2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG334551 Sulfate M300 0 - Ion Chromatography DC Sample required dilution Non - target analyte exceeded <br />calibration range <br />REPAD 15 06.05 01 <br />Page 21 of 34 <br />