Doc Name
QA Monitoring and Test Results- LOB Liner Extension- Cover to Append. G.1
From
CC&V
To
DRMS
Email Name
TC1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ameO <br />4.1.1 Grain Size Distribution <br />AMEC completed the grain size distribution (gradation) of a sample of BF. The results of <br />gradation analyses are presented in Appendix E and summarized in Table 4. <br />■ AMEC performed 1 CQA gradation of BF for the LOB Liner Extension. The testing <br />frequency (approximately one test per 3,179 cubic yards) exceeded the minimum <br />specified testing frequency of one test per 10,000 cubic yards. The CQA gradations <br />performed of BF met project specifications. The SLF CQA gradation results are <br />presented in Appendix G and summarized in Table 4. <br />4.1.2 Moisture Content <br />AMEC measured oven moisture content of BF as part of the CQA program. Moisture content <br />data are presented in Appendix E. <br />4.1.3 Atterberg Limits <br />AMEC performed Atterberg limit testing of all fill materials. All fill materials were non - plastic. <br />The BF sample tested met project specifications for Atterberg Limits. <br />The BF Atterberg limits testing frequency (approximately one test per 300 cubic yards) <br />exceeded the minimum specified testing frequency of one test per 5,000 cubic yards. The <br />plasticity index of the CQA BF sample met the project specification of plasticity index greater <br />than or equal to 10. Atterberg limit test results for BF are presented in Appendix E and <br />summarized in Table 4. <br />4.1.4 Proctor Compaction Tests <br />AMEC performed standard Proctor compaction tests of BF in order to compare in -place <br />densities and moisture contents with laboratory determined values of maximum dry density and <br />optimum moisture content. AMEC performed 1 CQA Standard Proctor compaction tests of BF. <br />Proctor compaction testing was not specified for BF. Approximately one test per 3,179 cubic <br />yards was performed. The BF compaction test results are presented in Appendix E and <br />summarized in Table 4. CQC Proctor tests were not included in the Proctor testing frequency. <br />4.2 Field Testing and Monitoring <br />AMEC observed all fill operations in the construction to verify, when necessary, lift thickness, <br />adequate compaction, and acceptable moisture conditions. AMEC standardized nuclear <br />gauges at the start of each day's work according to ASTM D2922. <br />10 <br />