My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-12-27_REPORT - M1980244 (16)
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2012-12-27_REPORT - M1980244 (16)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:11:41 PM
Creation date
1/8/2013 12:22:11 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REPORT
Doc Date
12/27/2012
Doc Name
QA Mon. & Test Results, Ph. 5 Berm Mod.- Cover to Append E, Specs.
From
CC&V
To
DRMS
Email Name
TC1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ameO <br />4.1.3 Atterberg Limits <br />AMEC performed Atterberg limits testing of the fill materials. All fill materials, with the <br />exception of SLF, were non - plastic. The SSF sample tested met project specifications for <br />Atterberg limits. Atterberg limits test data are presented in Appendix H.1. <br />AMEC performed one (1) CQA Atterberg limits test of SSF. The testing frequency <br />(approximately one test per 925 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 50,000 cubic yards. The CQA Atterberg limits performed on SSF <br />met project specifications. The SSF CQA Atterberg limits results are presented in <br />Appendix H.1 and summarized in Table 5. <br />AMEC performed four (4) CQA Atterberg limits tests of SLF. The testing frequency <br />(approximately one test per 118 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 4,000 cubic yards. The CQA Atterberg limits performed of SLF <br />met project specifications. The SLF CQA Atterberg limits results are presented in <br />Appendix H.1 and summarized in Table 6. <br />4.1.4 Proctor Compaction Tests <br />AMEC performed standard Proctor compaction tests of SLF in order to compare in -place <br />densities and moisture contents with laboratory derived values of maximum dry density and <br />optimum moisture content. <br />AMEC performed four (4) CQA standard Proctor compaction tests of SLF. The testing <br />frequency (approximately one test per 118 cubic yards) exceeded the minimum specified <br />testing frequency of one test per 4,000 cubic yards. The SLF compaction test results met <br />project specifications and are presented in Appendix H.2 and summarized in Table 6. CQC <br />Proctor tests were not included in the Proctor testing frequency.The SSF fill contained more <br />than 30 percent above the % -inch sieve. Per Specification 2200 Section 3.06, SSF <br />containing more than 30 percent above the 3/4 -inch sieve is placed using a method <br />specification and cannot be tested using a standard Proctor (due to the high rock content). <br />AMEC Environment & Infrastructure, Inc. <br />2000 S. Colorado Blvd 2 -1000 <br />Denver, CO 80222 <br />Tel 303 - 935 -6505 <br />Fax 303 - 935 -6575 vA w.amec.com <br />13 <br />