My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-12-27_REPORT - M1980244 (16)
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2012-12-27_REPORT - M1980244 (16)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:11:41 PM
Creation date
1/8/2013 12:22:11 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REPORT
Doc Date
12/27/2012
Doc Name
QA Mon. & Test Results, Ph. 5 Berm Mod.- Cover to Append E, Specs.
From
CC&V
To
DRMS
Email Name
TC1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Am '' <br />WTI I <br />• Standard Proctor compaction (ASTM D698); <br />• Permeability (ASTM D5O84, Method D); <br />• In -place density testing (ASTM D2922); <br />• Soil description (ASTM D2488); <br />• Bulk specific gravity (ASTM C127); and <br />AMEC conducted appropriate tests as required by the specifications for SSF and SLF. <br />The laboratory test results are summarized in Tables 5 and 6 and are presented in <br />Appendix H. <br />4.1.1 Grain Size Distribution <br />AMEC analyzed the grain size distribution (gradation) of samples of SSF and SLF. The <br />results of gradation analyses are presented in Appendix H.1 and summarized in Tables 5 <br />and 6. <br />AMEC performed one (1) CQA gradation of SSF. The testing frequency (approximately one <br />test per 925 cubic yards) exceeded the minimum specified testing frequency of one test per <br />50,000 cubic yards. The SSF CQA gradation results met project specifications and the <br />results are presented in Appendix H.1 and summarized in Table 5. <br />AMEC performed four (4) CQA gradations of SLF. The testing frequency (approximately <br />one test per 118 cubic yards) exceeded the minimum specified testing frequency of one test <br />per 4,000 cubic yards. The SLF CQA gradation results met project specifications and are <br />presented in Appendix H.1 and summarized in Table 6. <br />4.1.2 Moisture Content <br />AMEC measured oven moisture contents of SSF and SLF as part of the CQA program. <br />Moisture content data are presented in Appendix H.1 and Tables 5 and 6. <br />AMEC Environment & Infrastructure, Inc. <br />2000 S. Colorado Blvd 2 -1000 <br />Denver, CO 80222 <br />Tel 303 - 935 -6505 <br />Fax 303 - 935 -6575 www.amec.com <br />12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.