ame0 <br />AMEC performed one (1) CQA Atterberg limits tests of PBM. The testing frequency <br />(approximately one test per 9,040 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 10,000 cubic yards. The PBM CQA Atterberg limits met project <br />specifications, and the results are presented in Appendix H.1 and summarized in Table 6. <br />AMEC performed five (5) CQA Atterberg limits tests of SLF. The testing frequency <br />(approximately one test per 1,028 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 4,000 cubic yards. The CQA Atterberg limits performed of SLF <br />met project specifications. The SLF CQA Atterberg limits results are presented in <br />Appendix H.1 and summarized in Table 7. <br />AMEC performed two (2) CQA Atterberg limits tests of DCF. The testing frequency <br />(approximately one test per 5,404 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 20,000 cubic yards. The DCF CQA Atterberg limits met project <br />specifications, and the results are presented in Appendix H.1 and summarized in Table 8. <br />AMEC performed four (4) CQA Atterberg limits test of SSF. The testing frequency <br />(approximately one test per 20,955 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 50,000 cubic yards. The SSF CQA Atterberg limits met project <br />specifications, and the results are presented in Appendix H.1 and summarized in Table 9. <br />4.1.4 Proctor Compaction Tests <br />AMEC performed standard Proctor compaction tests of SLF in order to compare in -place <br />densities and moisture contents with laboratory derived values of maximum dry density and <br />optimum moisture content. <br />AMEC performed one (1) CQA standard Proctor compaction tests of PBM. The testing <br />frequency (approximately one test per 9,040 cubic yards) exceeded the minimum specified <br />testing frequency of one test per 10,000 cubic yards. The PBM compaction test results met <br />project specifications and are presented in Appendix H.2 and summarized in Table 6. <br />AMEC Environment & Infrastructure, Inc. <br />2000 S. Colorado Blvd 2 -1000 <br />Denver, CO 80222 <br />Tel 303 - 935 -6505 <br />Fax 303 - 935 -6575 www.amec corn 17 <br />