My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-12-27_REPORT - M1980244 (11)
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2012-12-27_REPORT - M1980244 (11)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:11:41 PM
Creation date
1/7/2013 1:51:44 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REPORT
Doc Date
12/27/2012
Doc Name
QA Mon. & Test Results, (PSES)- Section 1- Cover to Append. B.2 Doc. Photos.
From
CC&V
To
DRMS
Email Name
TC1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Standard Proctor compaction (ASTM D698); <br />• Permeability (ASTM D5084, Method D); <br />• In -place density testing (ASTM D2922); <br />• Soil description (ASTM D2488); <br />• Bulk specific gravity (ASTM C127); and <br />• Point load strength index (ASTM D5731, Method D). <br />AMEC conducted appropriate tests as required by the specifications for SF, PBM, SLF, <br />DCF, and SSF. <br />The laboratory test results are summarized in Tables 5 through 9 and are presented in <br />Appendix H. <br />4.1.1 Grain Size Distribution <br />ame0 <br />AMEC analyzed the grain size distribution (gradation) of samples of SF, PBM, SLF, DCF, <br />and SSF. The results of gradation analyses are presented in Appendix H.1 and <br />summarized in Tables 5 through 9. <br />AMEC performed two (2) CQA gradations of SF. The testing frequency (approximately one <br />test per 16,900 cubic yards) exceeded the minimum specified testing frequency of one test <br />per 50,000 cubic yards. The SF CQA gradation results met project specifications and the <br />results are presented in Appendix H.1 and summarized in Table 5. <br />AMEC performed one (1) CQA gradation of PBM. The testing frequency (approximately one <br />test per 9,040 cubic yards) exceeded the minimum specified testing frequency of one test <br />per 10,000 cubic yards. The PBM CQA gradations met project specifications, and the <br />results are presented in Appendix H.1 and summarized in Table 6. <br />AMEC performed five (5) CQA gradations of SLF. The testing frequency (approximately one <br />test per 1,028 cubic yards) exceeded the minimum specified testing frequency of one test <br />AMEC Environment & Infrastructure, Inc. <br />2000 S Colorado Blvd 2 -1000 <br />Denver, CO 80222 <br />Tel 303 - 935 -6505 <br />Fax 303 - 935 -6575 www amec.com 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.