Laserfiche WebLink
Acz <br />2773 Downhill Drive Steamboat Spnngs, CO 80487(800) 334 -5493 <br />Rio Grande Silver, Inc. <br />Project ID: S12064 <br />Sample ID: WRSF -C <br />Inorganic Prep <br />Parameter <br />EPA Method <br />Result Qual XQ Units MDL PQL Date Analyst <br />Total Hot Plate <br />Digestion <br />Total Hot Plate <br />Digestion <br />Metals Analysis <br />Aluminum (1312) <br />Antimony (1312) <br />Arsenic (1312) <br />Barium (1312) <br />Beryllium (1312) <br />Boron (1312) <br />Cadmium (1312) <br />Calcium (1312) <br />Chromium (1312) <br />Cobalt (1312) <br />Copper (1312) <br />Iron (1312) <br />Lead (1312) <br />Magnesium (1312) <br />Manganese (1312) <br />Mercury (1312) <br />Molybdenum (1312) <br />Nickel (1312) <br />Potassium (1312) <br />Selenium (1312) <br />Silica (1312) <br />Silicon (1312) <br />Silver (1312) <br />Sodium (1312) <br />Thallium (1312) <br />Uranium (1312) <br />Zinc (1312) <br />Laboratories, Inc. <br />M3010A ICP <br />M3010A ICP -MS <br />Parameter <br />EPA Method <br />Result Qual XQ Units <br />MDL PQL Date Analyst <br />M6010B ICP <br />M6020 ICP -MS <br />M6020 ICP -MS <br />M6010B ICP <br />M6020 ICP -MS <br />M6010B ICP <br />M6020 ICP -MS <br />M6010B ICP <br />M6020 ICP -MS <br />M6010B ICP <br />M6020 ICP -MS <br />M6010B ICP <br />M6020 ICP -MS <br />M6010B ICP <br />M6010B ICP <br />M7470A CVAA <br />M6010B ICP <br />M6010B ICP <br />M6010B ICP <br />M6020 ICP -MS <br />M6010B ICP <br />M200 7 ICP (Calc S102) <br />M6020 ICP -MS <br />M6010B ICP <br />M6020 ICP -MS <br />M6020 ICP -MS <br />M6020 ICP -MS <br />0.74 mg /L <br />U • mg /L <br />0.0007 B * mg /L <br />0.007 B * mg /L <br />U • mg /L <br />U * mg /L <br />U * mg /L <br />5 1 mg /L <br />U * mg /L <br />1J * mg /L <br />0.0006 B * mg /L <br />0 09 * mg /L <br />0 0002 B * mg /L <br />0 3 B * mg /L <br />U * mg /L <br />U * mg /L <br />U * mg /L <br />U * mg /L <br />3 0 * mg /L <br />0 0001 B * mg /L <br />7 3 mg /L <br />3.4 mg /L <br />U * mg /L <br />U * mg /L <br />U * mg /L <br />0.0002 B * mg /L <br />0 002 B * mg /L <br />ACZ Sample ID: <br />Date Sampled: <br />Date Received: <br />Sample Matrix: <br />Inorganic Analytical <br />Results <br />0 03 <br />0 0004 <br />0 0002 <br />0 003 <br />0 00005 <br />001 <br />0 0001 <br />02 <br />0.0005 <br />001 <br />0 0005 <br />0 02 <br />0.0001 <br />02 <br />0.005 <br />0.0002 <br />001 <br />001 <br />03 <br />0.0001 <br />04 <br />02 <br />0 00005 <br />03 <br />0 0001 <br />0 0001 <br />0.002 <br />02 <br />0 002 <br />0 001 <br />0 02 <br />0 0003 <br />0 05 <br />0 0005 <br />1 <br />0.002 <br />0 05 <br />0 003 <br />0 05 <br />0.0005 <br />1 <br />0 03 <br />0 001 <br />0 05 <br />0 05 <br />2 <br />0 0003 <br />2 <br />09 <br />0.0003 <br />2 <br />0.0005 <br />0.0005 <br />0 005 <br />L97087 -03 <br />09/28/12 13:56 <br />10/02/12 <br />Soil <br />10/18/12 12:11 <br />10/15/12 11 19 mfm <br />10/19/12 1007 <br />10/18/12 18.43 <br />10/18/12 1843 <br />10/19/12 10 07 <br />10/18/12 18 43 <br />10/19/12 10.07 <br />10/18/12 18:43 <br />10/19/12 1007 <br />10/18/12 18 43 <br />10/19/12 10 07 <br />10/18/12 18:43 <br />10/19/12 10:07 <br />10/18/12 18 43 <br />10/19/12 10 07 <br />10/19/12 10 07 <br />10/19/12 14.35 <br />10/19/12 10:07 <br />10/19/12 10:07 <br />10/19/12 10:07 <br />10/18/12 18:43 <br />10/19/12 10:07 <br />10/22/12 11:40 <br />10/18/12 1843 <br />10/19/12 10 07 <br />10/18/12 18:43 <br />10/18/12 18 43 <br />10/18/12 18 43 <br />aeb <br />aeb <br />pmc <br />pmc <br />aeb <br />pmc <br />aeb <br />pmc <br />aeb <br />pmc <br />aeb <br />pmc <br />aeb <br />pmc <br />aeb <br />aeb <br />erf <br />aeb <br />aeb <br />aeb <br />pmc <br />aeb <br />calc <br />pmc <br />aeb <br />pmc <br />pmc <br />pmc <br />REPIN 02 06 05 01 *Please refer to Qualifier Reports for details <br />Page 9 of 57 <br />