Laserfiche WebLink
ENERGY <br />AHw a,111 <br />Qualifiers: <br />RL - Analyte reporting limit <br />ND - Not detected at the reporting limit. <br />www.energytab.com ! Helena, MT 877- 472 -0711 • Billings, MT 800 - 735 -4489 • Casper, WY 888- 235 -9515 <br />Aasrjtlsat Frahm SACe 1352 J Gillette, WY 866 - 888 - 7175 • Rapid City, SD 888 -672 -1225 • College Station, TX 888- 690 -2218 <br />QA /QC Summary Report <br />Prepared by Casper, WY Branch <br />Client: Cotter Corporation Report Date: 11/08/12 <br />Project: Schwartz SW 10/10/12 S26610 Work Order: C12100556 <br />r - <br />Analyte Count Result Units RL %REC Low Limit High Limit RPD RPDLimit Qual <br />Method: E200.7 <br />Sample ID: MB- 121024A 5 Method Blank <br />Sodium ND mg /L 0 3 <br />Run: ICP2-C_121024B <br />Batch: R166285 <br />10/24/12 12:14 <br />Sample ID: LFB- 121024A 5 Laboratory Fortified Blank Run: ICP2- C_121024B 10/24/12 12:18 <br />Calcium 49.0 mg /L 0.50 98 85 115 <br />Iron 0.988 mg /L 0.030 99 85 115 <br />Magnesium 48.5 mg /L 0.50 97 85 115 <br />Potassium 44.9 mg /L 0.50 90 85 115 <br />Sodium 47.1 mg /L 0.50 94 85 115 <br />Sample ID: C12100889- 004BMS2 5 Sample Matrix Spike Run: ICP2- C_121024B 10/24/12 20:10 <br />Calcium 500 mg /L 1.0 98 70 130 <br />Iron 9.94 mg /L 0.030 97 70 130 <br />Magnesium 508 mg /L 1.0 99 70 130 <br />Potassium 498 mg /L 1.0 96 70 130 <br />Sodium 2990 mg /L 3.2 70 130 A <br />Sample ID: C12100889 -004BMSD 5 Sample Matrix Spike Duplicate Run: ICP2- C_121024B 10/24/12 20:14 <br />Calcium 507 mg /L 1.0 99 70 130 1.4 20 <br />Iron 10.3 mg /L 0.030 100 70 130 3.4 20 <br />Magnesium 500 mg /L 1.0 98 70 130 1.7 20 <br />Potassium 491 mg /L 1.0 95 70 130 1.4 20 <br />Sodium 3020 mg /L 3.2 70 130 0.8 20 A <br />Method: E200.7 Analytical Run: ICP2- C_121030A <br />Sample ID: ICV Initial Calibration Verification Standard 10/30/12 12:59 <br />Aluminum 4.80 mg /L 0.10 96 95 105 <br />Sample ID: ICSA Interference Check Sample A 10/30/12 13:40 <br />Aluminum 506 mg /L 0.10 101 80 120 <br />Sample ID: ICSAB Interference Check Sample AB 10/30/12 13:44 <br />Aluminum 511 mg /L 0.10 102 80 120 <br />Method: E200.7 Batch: R166525 <br />Sample ID: MB- 121030A Method Blank Run: ICP2- C_121030A 10/30/12 14.04 <br />Aluminum ND mg /L 0.01 <br />Sample ID: LFB- 121030A Laboratory Fortified Blank Run: ICP2- C_121030A 10/30/12 14:08 <br />Aluminum 0.950 mg /L 010 95 85 115 <br />Sample ID: C12100563- 003CMS2 Sample Matrix Spike Run: ICP2- C_121030A 10/30/12 16:11 <br />Aluminum 0.982 mg /L 0.030 96 70 130 <br />Sample ID: 012100563- 003CMSD Sample Matrix Spike Duplicate Run: ICP2- C_121030A 10/30/12 16:15 <br />Aluminum 0.994 mg /L 0.030 98 70 130 1.2 20 <br />A - The analyte level was greater than four times the spike level. In <br />accordance with the method % recovery is not calculated. <br />MDC - Minimum detectable concentration <br />Page 11 of 25 <br />