frequency of one test per 50,000 cubic yards. The CQA Atterberg limits performed on SF <br />met project specifications. The SF CQA Atterberg limits results are summarized in Table 5. <br />AMEC performed two (2) CQA Atterberg limits tests of LDF. The testing frequency <br />(approximately one test per 70 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 10,000 cubic yards. The LDF CQA Atterberg limits met project <br />specifications, and the results are presented in Appendix H -1 and summarized in Table 6. <br />AMEC performed sixty -seven (67) CQA Atterberg limits tests of SLF. The testing frequency <br />(approximately one test per 1,633 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 5,000 cubic yards. The CQA Atterberg limits performed of SLF <br />met project specifications. The SLF CQA Atterberg limits results are presented in <br />Appendix H -1 and summarized in Table 7. <br />AMEC performed twelve (12) CQA Atterberg limits tests of DCF. The testing frequency <br />(approximately one test per 16,834 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 20,000 cubic yards. The DCF CQA Atterberg limits met project <br />specifications, and the results are presented in Appendix H -1 and summarized in Table 8. <br />AMEC performed one (1) CQA Atterberg limits test of SSF. The testing frequency <br />(approximately one test per 315 cubic yards) exceeded the minimum specified testing <br />frequency of one test per 50,000 cubic yards. The SSF CQA Atterberg limits met project <br />specifications, and the results are presented in Appendix H -1 and summarized in Table 9. <br />4.1.4 Proctor Compaction Tests <br />AMEC Earth & Environmental, Inc <br />2000 S. Colorado Blvd 2 -1000 <br />Denver, CO 80222 <br />Tel 303 - 935 -6505 <br />Fax 303 - 935 -6575 <br />ame9 <br />AMEC performed standard Proctor compaction tests of SF in order to compare in -place <br />densities and moisture contents with laboratory derived values of maximum dry density and <br />optimum moisture content. The majority of the SF contained more than 30 percent above <br />the 3/4-inch sieve. Per Specification 2200 Section 3.06, SF containing more than 30 percent <br />above the 3/4-inch sieve is placed using a method specification and cannot be tested using a <br />standard Proctor (due to the high rock content). Of the SF placed containing less than 30 <br />www.amec com 19 <br />