My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-08-21_HYDROLOGY - P2011003
DRMS
>
Day Forward
>
Hydrology
>
Prospect
>
P2011003
>
2012-08-21_HYDROLOGY - P2011003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:05:37 PM
Creation date
9/12/2012 12:27:28 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
P2011003
IBM Index Class Name
HYDROLOGY
Doc Date
8/21/2012
Doc Name
WQ SAMPLING RESULTS
From
KARMEN KING
To
DRMS
Email Name
RCO
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />The Mining Company <br />ADZ R) W ORKNUM PARAMETER <br />ETHOD . C1 UAL : DES <br />P <br />1.96680 - WG327666 Phenol <br />WG326943 Lead, potentially dissolved <br />REPAD.15.06.05.01 <br />WG326822 Manganese, total recoverable <br />420.4, Manual Distillation <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />Inorganic E)cterided <br />ACZ Project ID: L95680 <br />DJ Sample dilution required due to insufficient sample. <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG327591 Mercury, total M245 1 CVAA MA Recovery for either the spike or spike duplicate was outside <br />of the acceptance limits, the RPD was within the <br />acceptance limits <br />WG327049 Zinc, potentially dissolved M200.8 ICP -MS M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG326414 Biochemical Oxygen Demand (5 day) SM5210B A2 Sample incubation period exceeded method requirement <br />SM5210B HF BOD analysis performed outside of 24 -hour hold time <br />stated in the method but within 48 -hour hold time stated in <br />40 CFR <br />WG326634 Chemical Oxygen Demand M410.4 M2 Matrx spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M410.4 RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327464 Chloride SM4500CI -E RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327218 Cyanide, total M335 4 - Colorimetnc w/ LA Recovery for target analyte in the control sample (LCS or <br />distillation LFB) exceeded the acceptance criteria. Target analyte was <br />not detected in the sample [< MDL]. <br />M335.4 - Colorimetnc w/ M2 Matrix spike recovery was low, the recovery of the <br />distillation associated control sample (LCS or LFB) was acceptable. <br />M335.4 - Colorimetnc w/ RA Relative Percent Difference (RPD) was not used for data <br />distillation validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG327318 Cyanide, WAD SM4500 -CN I- Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br />distillation validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG326346 Dissolved Chromium, Hexavalent SM3500Cr -D H3 Sample was received and analyzed past holding time. <br />SM3500Cr -D RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG327082 Fluonde SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG326402 Nitrate /Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG327385 Nitrogen, ammonia M350.1 - Automated Phenate RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327248 Nitrogen, total Kjeldahl M351.2 - TKN by Block Digester RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327731 Phenol 420.4, Manual Distillation RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG326421 Residue, Non - Filterable (TSS) @105C SM2540D RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG326532 Sulfide as S SM4500S2 -D RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Page 22 of 54 <br />
The URL can be used to link to this page
Your browser does not support the video tag.