Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />The Mining Company <br />ACID ": WORKNJM PARAtiAETER <br />DUAL \ DESCRIP11 € <br />L95680 - WG328222 Lead, potentially dissolved <br />WG326822 Manganese, total recoverable <br />REPAD.15.06.05.01 <br />WG327591 Mercury, total <br />M200.8 ICP -MS <br />M200 8 ICP -MS <br />Inorganic Extend d <br />O v AAO � AAA � A <br />Qualifier Rep' <br />ACZ Project ID: L95680 <br />N1 See Case Narrative. <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />M245.1 CVAA MA Recovery for either the spike or spike duplicate was outside <br />of the acceptance limits; the RPD was within the <br />acceptance limits. <br />WG326414 Biochemical Oxygen Demand (5 day) SM5210B A2 Sample incubation period exceeded method requirement. <br />SM5210B HF BOD analysis performed outside of 24 -hour hold time <br />stated in the method but within 48 -hour hold time stated in <br />40 CFR <br />WG326634 Chemical Oxygen Demand M410.4 M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M410.4 RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327464 Chloride SM4500CI -E RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327218 Cyanide, total M335.4 - Colorimetric w/ LA Recovery for target analyte in the control sample (LCS or <br />distillation LFB) exceeded the acceptance critena Target analyte was <br />not detected in the sample [< MDL]. <br />M335.4 - Colorimetric w/ M2 Matrix spike recovery was low, the recovery of the <br />distillaton associated control sample (LCS or LFB) was acceptable. <br />M335.4 - Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br />distillation validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327231 Cyanide, WAD SM4500 -CN I- Colorimetric w/ RA Relative Percent Difference (RPD) was not used for data <br />distillation validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG326346 Dissolved Chromium, Hexavalent SM3500Cr -D H3 Sample was received and analyzed past holding time. <br />SM3500Cr -D RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG327082 Fluoride SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG326402 Nitrate /Nitrite as N, dissolved M353 2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327385 Nitrogen, ammonia M350.1 - Automated Phenate RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327248 Nitrogen, total Kleldahl M351 2 - TKN by Block Digester RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG327338 Phenol 420.4, Manual Distillation RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG326397 Residue, Non - Filterable (TSS) @105C SM2540D RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG326532 Sulfide as S SM4500S2 -D RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Page 21 of 54 <br />