4 a <br /> September 1997 Monthly Report <br /> Page 5 <br /> quantity targeted for treatment (ie. 1000-1100 G. P.M. ) . The <br /> treated flows for September ranged from 896 G.P.M. to 1077 <br /> G. P.M. . <br /> Attached are results from flow and quality monitoring of; <br /> Cement Creek diverted for treatment (CC-1B) ; American Tunnel <br /> flow before treatment (AT-INFEL) ; dissolved metals analysis of <br /> the AT-004 discharge; and Cement Creek below the AT-004 <br /> discharge point (CC-20) for August samples. The September <br /> results were not received by the date of this report and will <br /> be submitted with the October report. <br /> A picture of the Cement Creek diversion is attached. <br /> Mainstem Stream Monitoring and Reference Point Stream <br /> Monitoring <br /> Sunnyside sampled the reference point (A-72) on September 10, <br /> 1997 . These results and the results for the August 13 , 1997 <br /> samples from A-72 and the other three USGS gaging stations <br /> (A-68 , C-48 , and M-34) are attached. <br /> The provisional flow from the outside gage at A-72 for the <br /> August 13, 1997 sample was 346 cfs (previously reported as 101 <br /> cfs) , which is in the high flow category (Q> 300 cfs) and for <br /> September 10, 1997 was 163 cfs which is in the intermediate <br /> flow category (100 < Q < 300 cfs) . <br /> The reported zinc values which are an average of the result <br /> from two labs are August 13, 1997 - 283 ug/1 and September 10, <br /> 1997 - 330 ug/l. <br /> The index numbers for the August and September samples are <br /> calculated as follows: <br /> August September <br /> Xi = 283 Xi = 330 <br /> Xf = 306 Xf = 399 <br /> Sf = 104 Sf = 144 <br /> Ni=(Xi-Xf)/Sf Ni=(Xi-Xf)/Sf <br /> Ni=(283-306)/104 Ni=(330-399)/144 <br /> Ni= -0. 22 Ni= -0. 48 <br /> The index number graph and updated reporting table are attached. <br /> Evaluation of the normalized data: <br /> The index values of -0.22 and -0. 48 for August and September <br /> respectively indicate that water quality at the reference <br /> point was somewhat better than the reference data set for the <br /> respective flow classes. Additional evaluation or monitoring <br /> is not planned since the index numbers for August and <br /> September compare favorably with the data set. <br />