Laserfiche WebLink
AOZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Silver Star Resources, LLC <br />L92784-03 WG317138 <br />Manganese, dissolved <br />M200.7 ICP <br />WG317213 <br />Chloride <br />SM4500CI -E <br />WG317289 <br />Cyanide, total <br />M335.4 - Colorimetnc w/ <br />distillation <br />M335.4 - Colorimetric w/ <br />distillation <br />WG317287 <br />Cyanide, WAD <br />SM4500 -CN I- Cdorimetricw/ <br />distillation <br />WG317248 <br />Fluoride <br />SM450OF -C <br />WG317374 <br />Nitrate/Nitrite as N <br />M353.2 - H2SO4 preserved <br />WG316982 <br />Phosphorus, ortho dissolved <br />M365.1 - Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Add <br />WG316967 Residue, Nori-Fifterable (TSS) @105C SM2540D <br />WG317343 Sulfate D516- 02- Turbidimetric <br />L92784.04 WG317138 <br />WG317347 <br />WG317213 <br />WG317289 <br />WG317287 <br />WG317248 <br />WG317374 <br />WG316982 <br />Manganese, dissolved <br />Silver, dissolved <br />Chloride <br />Cyanide, total <br />Cyanide, WAD <br />Fluoride <br />Nitrate/Nitrite as N <br />Phosphorus, ortho dissolved <br />M200.7 ICP <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />SM4500CI -E <br />M335.4 - Colorimetric w/ <br />distillation <br />M335.4 - Colorimetric w/ <br />distillation <br />SM4500•CN I- Cdorimetricw/ <br />distillation <br />SM450OF -C <br />M353.2 - H2SO4 preserved <br />M365.1 - Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Acid <br />WG316967 Residue, Non- Fifterable (TSS) @105C SM2540D <br />WG317343 Sulfate D516- 02- Turbidimetric <br />REPAD.15.06.05.01 <br />ACZ Project ID: L92784 <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 O MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />H3 Sample was received and analyzed past holding time. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />ZA Poor recovery for Silver quality control is accepted due to <br />low Silver solubility in samples, digestates, or extracts that <br />do not contain sufficient Hydrochloric add. <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< IOx MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< IOx MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />H3 Sample was received and analyzed past holding time. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />Page 29 of 37 <br />