Laserfiche WebLink
Typical SEDCAD+ Input <br /> Diversions and Impoundments <br /> Line Typical <br /> Code Parameter Input <br /> POND: <br /> 15 Time increment; "1"; dead space; 0.1; 1; 20; 0; 1; 1 <br /> volume; elev; ems volume - 0 = no volume <br /> calculated by digitizer 1 = volume to <br /> follow - calculated by digitizer <br /> elev - 0 = no elevation data entered (only <br /> stage data) 1 = elevation data to follow <br /> ems - 0 = no emergency spillway at this <br /> structure 1 = emergency spillway and <br /> parameters will follow <br /> 16 1111f; "0"; # stage points; "500"; 1; 0; As measured; 500; 1; <br /> discharge opt; hydrograph print opt; 1; 2; 0 <br /> CSTRS hydrograph print option - "1"=No, <br /> "2"=Yes <br /> Discharge opt - 1 = input own discharge <br /> 2 = Drop inlet <br /> 3 = trickle tube <br /> 4 = perforated riser <br /> CSTRS - number of continuous stirred type <br /> reactors: <br /> "0" if running hydrology only! (will not run <br /> unless this is 0) <br /> "0" if running DEPOSITS (hydrology & <br /> sedimentology) <br /> "2" if running CSTRs (hydrology & <br /> sedimentology) <br /> 17 Elev 1, elev. 2, . . . up to number of stage <br /> stage points (This line is skipped As applicable, As <br /> if elev in line code 15 is 0] applicable, . . . etc. <br /> 18 Stage 1, stage 2, . . . up to number As applicable; As <br /> of stage points applicable, . . . etc. <br /> Revised 05/24/91 <br />