Laserfiche WebLink
carried out on a 100 -foot by 100 -foot grid with additional survey points required to define valley <br />leach facility topographic features (i.e., toe of slope, crest of slope, breaks in grade), unless otherwise <br />directed by MANAGER. The Record Drawings shall include elevations and locations for the <br />following: <br />• Underdrain plan view showing the limits of the valley leach facility. Underdrain Fill <br />and underdrain alignment, with elevations every approximately 100 feet or on every <br />break in grade <br />• Diversion channel plan and profile view along the diversion channel alignment <br />• Leak detection trench plan view showing the limits of the valley leach facility, leak <br />detection trench alignment, and leak detection sumps, with elevations every <br />approximately 100 -feet <br />• Perimeter access roads <br />• Top of Upper geosynthetics in the Pregnant Solution Storage Area, including the <br />Vertical Riser Sump and base plates <br />• High Volume Solution Collection piping plan showing the limits of the VLF, and <br />piping alignment with elevation every approximately 100 -feet <br />In addition, the Colorado licensed surveyor will provide a surveyor's certificate to be submitted in the <br />Construction Certification Report. <br />C. Submittal: <br />Soil Liner Fill plan view showing the limits of the valley leach facility, with <br />contours of the Soil Liner Fill and Bedding Fill surface on a 10 -foot contour interval, <br />including the regraded ore slopes and end berms <br />Low Volume Solution Collection piping plan showing the limits of the composite <br />liner, double liner and single liner, and piping alignment with elevations every <br />approximately 100 feet <br />CONTRACTOR will submit completed as -built documentation within seven (7) calendar days upon <br />completion of the work in the following manner: <br />1. Submit two (2) hard copies to the MANAGER. <br />2. Submit two (2) non - reproducible copies to the MANAGER in electronic form on <br />compact disks (CD) or DVD's and in an AutoCAD compatible format. <br />D. The CONTRACTOR will be responsible for performing the following survey activities associated <br />with the Construction Certification Report: <br />1. Provide northing, easting, and elevation for all Soil Liner Fill depth verifications. <br />2. Provide northing, easting, and elevation for geomembrane panel intersections and <br />destructive samples. <br />Section 01050 Page 2 of 3 January 14, 2011 <br />Construction Staking Revision 0 <br />S \Protects \1125G Squaw Gulch Valley Leach Facililty Design \I - Tech Specs \01050 r1 doc <br />amec9 <br />