ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Matheson Mining Consultants <br />L68214 - WG242095 Acidity as CaCO3 <br />WG242149 Chloride <br />SM2310B - Titration <br />325.2 / SM4500CI -E <br />Inorganic Extended <br />Qualifier Report <br />ACZ Project ID: L68214 <br />ACZ ID WORKNUM PARAMETER <br />METHOD QUAL DESCRIPTION <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />325.2 / SM4500CI -E RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG241669 Coliforms, fecal SM9222D - Membrane Filter HE Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />WG241971 Fluoride SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG241702 Nitrate /Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG242032 Nitrogen, ammonia M350.1 - Automated Phenate RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG242149 Sulfate 375.4 - Turbidimetric M4 The spiked sample required a dilution such that the spike <br />recovery calculation does not provide useful information. <br />The recovery of the associated control sample (LCS or <br />LFB) was acceptable. <br />375.4 - Turbidimetric RD For a solid matrix, the duplicate RPD (spike or matrix) <br />exceeded the control limit, which is attributable to the non - <br />homogeneity of the sample. <br />WG241741 Total Alkalinity SM2320B - Titration B4 Target analyte detected in blank at or above the <br />acceptance criteria. <br />L68214 -03 WG242095 Acidity as CaCO3 SM2310B - Titration RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG242149 Chloride 325.2 / SM4500CI -E M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />325.2 / SM4500C1 -E RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG241971 Fluoride SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG241702 Nitrate /Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG242032 Nitrogen, ammonia M350.1 - Automated Phenate RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG242149 Sulfate 375.4 - Turbidimetric M4 The spiked sample required a dilution such that the spike <br />recovery calculation does not provide useful information. <br />The recovery of the associated control sample (LCS or <br />LFB) was acceptable. <br />375.4 - Turbidimetric RD For a solid matrix, the duplicate RPD (spike or matrix) <br />exceeded the control limit, which is attributable to the non - <br />homogeneity of the sample. <br />WG241741 Total Alkalinity SM2320B - Titration B4 Target analyte detected in blank at or above the <br />acceptance criteria. <br />REPAD.15.06.05.01 <br />L68214: Page 36 of 51 <br />