My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-04-23_GENERAL DOCUMENTS - M1977247 (2)
DRMS
>
Day Forward
>
General Documents
>
Minerals
>
M1977247
>
2008-04-23_GENERAL DOCUMENTS - M1977247 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:28:25 PM
Creation date
10/14/2011 8:54:12 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977247
IBM Index Class Name
GENERAL DOCUMENTS
Doc Date
4/23/2008
Doc Name
Appendix II- ACZ Labs Water Analysis Results
From
Holcim
To
DRMS
Permit Index Doc Type
General Correspondence
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />ACZ Laboratories, Inc. <br />410 2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Matheson Mining Consultants <br />ACZ ID WORKNUM _ PARAMETER METHOD <br />QUAL DESCRIPTION <br />MA Recovery for either the spike or spike duplicate was outside <br />of the acceptance limits; the RPD was within the <br />acceptance limits. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />325.2 / SM4500CI -E RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG241669 Coliforms, fecal SM9222D - Membrane Filter HE Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />WG241971 Fluoride SM4500F -C RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG241702 Nitrate /Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Nitrite as N, dissolved M353.2 - Automated Cadmium RA Relative Percent Difference (RPD) was not used for data <br />Reduction validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG242032 Nitrogen, ammonia M350.1 - Automated Phenate RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG242149 Sulfate 375.4 - Turbidimetric M4 The spiked sample required a dilution such that the spike <br />recovery calculation does not provide useful information. <br />The recovery of the associated control sample (LCS or <br />LFB) was acceptable. <br />375.4 - Turbidimetric RD For a solid matrix, the duplicate RPD (spike or matrix) <br />exceeded the control limit, which is attributable to the non - <br />homogeneity of the sample. <br />WG241741 Total Alkalinity SM2320B - Titration B4 Target analyte detected in blank at or above the <br />acceptance criteria. <br />L68214-01 WG241703 Mercury, dissolved <br />WG242095 Acidity as CaCO3 <br />WG242149 Chloride <br />REPAD.15.06.05.01 <br />M245.1 CVAA <br />SM2310B - Titration <br />325.2 / SM4500CI -E <br />I norganic Extended <br />ualifier Report <br />ACZ Project ID: L68214 <br />L68214: Page 35 of 51 <br />
The URL can be used to link to this page
Your browser does not support the video tag.