Laserfiche WebLink
• <br />• <br />• <br />Basement- A crack was noted extending east/west approximately eight feet south of the basement <br />doorway entrance near the northern most basement window. A hairline crack was also noted <br />extending from the bottom north corner of the north most window on the west foundation wall <br />approximately eight inches. A hairline crack was noted extending approximately four inches from <br />the top north corner of the north most basement window on the west foundation. A similar crack <br />was also noted extending from the top south corner of the north most window. A hairline crack was <br />noted extending to the slab from the bottom south corner of the north basement window. A hairline <br />crack extending east/west in the basement slab was noted in the middle of the basement. Another <br />hairline crack in the slab was noted extending east/west from the south hot water heater on the east <br />basement wall. A hairline crack was filmed on the upper north corner of the south most basement <br />window on the west foundation. A similar crack was also filmed extending from the bottom north <br />corner of the south most basement window on the west foundation. A crack was noted in the <br />middle of the foundation at the bottom of the south most window on the west foundation, extending <br />to the slab. Additionally a small hairline crack was found on the bottom south corner of the <br />foundation on the south most window on the west foundation. This crack extended approximately <br />six inches from the corner of the window frame. <br />A hairline crack was noted in the foundation at the bottom south corner of the south crawlspace <br />cut out extending from the bottom corner to the slab. Another hairline crack was noted on the <br />foundation in the bottom north corner of the south crawlspace cut out extending down to the <br />middle of the foundation wall. A hairline crack was noted in the foundation on the east wall <br />extending from the slab up the north side of the north crawlspace cut out to the top of the <br />foundation. A hairline crack was noted extending east/west in the concrete slab near the <br />walkway just east northeast of the basement stairs and south of the north water heater. Another <br />east/west hairline slab crack was noted just north of the north water heater. <br />Crawlspace- No pre - existing damage was noted in the crawlspace. <br />Sunroom (East)- A minor hairline crack was noted in the stamped concrete approximately three <br />feet south of the hot tub. Another hairline crack was noted in the stamped concrete near the <br />south entrance to the sunroom. The wood molding over the brick on the west side of the hot tub <br />had come loose from the ceiling approximately one inch. <br />Horse Barn <br />The roof beams on the northeast comer of the barn had been previously repaired by the <br />homeowner. <br />Residence Exterior <br />The stamped concrete on the southeast corner of the southeast patio is pitted and spalled. No <br />additional pre - existing structural or cosmetic damage was noted on the exterior. The soffitt is <br />loose and drooping on the southeast corner of the kitchen. The corner block on the southwest <br />corner of the foundation on the south side was cracked vertically. This cracked had previously <br />been sealed. There were some mortar joint separation cracks in the foundation blocks on the <br />west side near the southwest corner. Additional mortar joint separation cracks were seen in the <br />foundation between a few blocks between the basement windows on the west side. A vertical <br />foundation crack was noted on the west foundation of the garage about the middle of the garage. <br />Another vertical foundation crack was noted approximately three feet north of the previous <br />crack. No other pre - existing damage was noted on the exterior. <br />Please refer to the DVD for additional documentation. <br />