Laserfiche WebLink
Mr. Wallace H. Erickson <br />Response to August 23, 2011 Bird Memorandum <br />September 9, 2011 <br />Page 6 <br />dissolved solids using a method set forth in Actlabs geochemistry /assay and geometallurgy <br />protocols (www.actlabs.com) and approved by DRMS. <br />Adequacy Issue No. D. Attachment D -8, Whole Rock Sampling and Kinetic Testing <br />Work Plan <br />1) For all solids tests (e.g., SPLP, humidity cell, acid -base accounting, <br />whole rock analyses, solution characterization methods), the Applicant <br />must commit to consulting with the Division prior to the tests to <br />determine appropriate sampling and analytical parameters, including, but <br />not limited to, what is regarded as a representative sample, the <br />appropriate analytical suite for each test, and laboratories that are <br />qualified to perform the tests. <br />2) ABA: In addition to total sulfur all tests must include sulfide sulfur. <br />3) Humidity Cell Test: Collection of sample material for the tailings <br />humidity cell test must be done with the DRMS geochemist present. The <br />humidity cell test must be conducted under the conditions outlined in the <br />Division's adequacy review of 25 March 2011, i.e., the test must be run <br />indefinitely or until notified otherwise by the division and the analyte list <br />must be as described in the 25 March 2011 review. <br />Response to Adequacy Issue No. D. <br />Response to Adequacy Issue No. D.1. <br />Wildcat commits to consulting with DRMS for all solids tests (e.g., SPLP, <br />humidity cell, acid -base accounting, whole rock analyses, solution characterization <br />methods) prior to the tests to determine appropriate sampling and analytical parameters, <br />including, but not limited to, what is regarded as a representative sample, the appropriate <br />analytical suite for each test, and laboratories that are qualified to perform the tests. <br />Response to Adequacy Issue No. D.2. <br />Wildcat will include sulfide sulfur in the ABA protocol which also quantifies AP, <br />NP, Net NP, paste pH and acid soluble sulfate and sulfide. <br />Response to Adequacy Issue No. D.3. <br />Wildcat will collect sample material for the tailings humidity cell test with the <br />DRMS geochemist present. Wildcat will conduct the humidity cell test under the <br />conditions outlined in DRMS' March 25, 2011 adequacy review, i.e., the test will be run <br />indefinitely or until notified otherwise by DRMS, and the analyte list will be as <br />described in the March 25, 2011 review. <br />DEN 97,591,783v2 9 -9 -11 <br />GREENBERG TRAURIG, LLP • ATTORNEYS AT LAW • WWW.GTLAW.COM <br />