My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-08-08_REVISION - M1977493 (33)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1977493
>
2011-08-08_REVISION - M1977493 (33)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:36:39 PM
Creation date
8/9/2011 7:39:42 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977493
IBM Index Class Name
REVISION
Doc Date
8/8/2011
Doc Name
EPP Submittal
From
Climax Molybdenum
To
DRMS
Type & Sequence
TR18
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />• <br />Technical Revision (TR -18) Climax Molybdenum Company <br />Environmental Protection Plan Permit No. M- 1977 -493 <br />T - 3.2.3 Cleaner Frother <br />Cytec Oreprep F -579 Frother (or equivalent) will be used in the secondary mill regrind circuit as a flotation <br />frother. It is comprised of mixed polyglycols. Direct contact with this material may cause mild eye and <br />skin irritation, if ingested immediate medical attention should be obtained. This product may be replaced <br />with an equivalent product in the future. <br />Cytec Oreprep F -579 is a stable product that is completely soluble in water. Cytec Oreprep F -579 has a <br />National Fire Protection Agency rating of 1 for health and for fire, meaning that the material can cause <br />significant irritation and that the material must be preheated before ignition can occur. <br />Anticipated usage rates are 0.005 to 0.010 lb of cleaner frother per ton of ore processed. <br />Cleaner frother will be delivered to the mill site in 300 gallon totes. The totes will be transferred into a <br />cleaner frother storage tank (600 gallons). The cleaner frother will be stored in the reagent storage area <br />of the mill building (see Mill Building Detail - Area 450 on the south side of the mill building on Figure AM- <br />06-T-06). The cleaner frother storage tank will be located in the regrind /cleaner area of the mill building <br />(area 430 on the Mill Building Detail drawing on Figure AM- 06- T -06). Secondary containment will be <br />provided in the cleaner frother tote storage area (see Reagent Storage Area Detail Figure AM- 06- T -07). <br />Cleaner frother storage tank releases will be kept contained inside of the mill building and will pump to the <br />rougher concentrate thickener. <br />Tank level indication will be available locally as well as through the control system. The control system <br />will alarm for a given tank low and high level. <br />The cleaner frother totes will be stored in the warehouse in a containment area just north of Area 450 <br />(Reagent Storage Area Detail Figure AM- 06- T -07). This storage area will drain to a sump that does not <br />contain an installed sump pump. In the event of a release in this area, a pump will be placed in the <br />secondary containment sump and the cleaner frother will be routed back into the process circuit or <br />pumped into a suitable container for proper disposal through direction from the environmental <br />department. <br />In the event of a cleaner frother distribution system failure, the frother will be contained within the mill <br />building and will be sent to the rougher concentrate thickener. <br />T - 3.2.4 Iron Depressant <br />Orfom D8 Depressant is a mineral processing aid that will be used in the mill circuit to maintain separation <br />and suppress iron and other metals in the flotation process. This is a corrosive material that causes <br />irreversible eye and skin damage. The vapor is combustible, and may cause respiratory tract irritation if <br />inhaled. The material can be harmful or fatal if swallowed. <br />In the event of a spill, the area will be evacuated and monitored with a combustible gas indicator. Spills <br />will be contained and cleaned up as soon as possible using appropriate techniques, such as applying <br />non - combustible sorbent materials or pumping. The material will be used and stored only in well <br />ventilated areas that are not near heat, sparks, or open flames. <br />Anticipated usage rates are 0.025 to 0.045 lb of iron depressant per ton of ore processed. <br />The iron depressant will be stored in one tank with a capacity of 10,000 gallons. The iron depressant will <br />be stored in the reagent storage area of the mill building (see Mill Building Detail - Area 450 on the south <br />side of the mill building on Figures AM- 06 -T -06 and AM- 06- T -07). <br />Secondary containment with a volume greater than that of the tank will be provided in the reagent storage <br />area (see Reagent Storage Area Detail Figure AM- 06- T -07). Tank level indication will be available locally <br />as well as through the control system. The control system will alarm for a given tank low and high level. <br />A local alarm horn will sound for a given tank high level. <br />In the event of a storage tank failure, the iron depressant will be contained in the reagent storage area via <br />secondary containment. The secondary containment area is equipped with a sump but no sump pump. <br />In the event of a release in this area, a pump will be placed in the secondary containment sump and the <br />depressant will be routed back into the process circuit or pumped into a suitable container for proper <br />EPP: Revision R1 T -8 July 2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.