Laserfiche WebLink
separately was also unnecessary, though this was done for the Jensen property subunits. <br />All production samples were initially air dried for three weeks or more and then oven- <br />dried at 110 degrees Fahrenheit to a constant weight. Production samples will be <br />retained until the review process is complete. <br />Species Identification: <br />Voucher specimens were collected and confirmed or identified by Dr. William <br />A. Weber, retired Curator of the University of Colorado herbarium. Nomenclature <br />follows Dr. Weber's book Colorado Flora: Western Slope; 1987; Colorado Associated <br />University Press, Boulder. Co. Plant species that were encountered during cover <br />sampling are listed in Table 2 of the Appendix. <br />Statistical Evaluation: <br />The calculation of sample adequacy for cover samples followed methods <br />outlined on pages 20 and 21 of the Division's Bond Release Guidelines. Because <br />reclaimed community cover and production averages exceeded 90% of the <br />corresponding success standards, no hypothesis testing was required. <br />6