Response to Geochemistry Review - May Day Conversion CN-1
<br />File No. M-1981-185
<br />underground disposal option, the operator should commence the test as soon as possible. The
<br />Division will not allow any permanent underground disposal of tailings until at least one year's
<br />worth of data have been produced from the humidity cell test.
<br />The following table provides the humidity test protocols for analytes and frequency of analyses.
<br />The operator must refer to ASMT method D5744-07 for the required testing methodology. As
<br />this is a standardized ASTM test, there are certified laboratories available that have the capability
<br />and expertise to conduct this type of test.
<br />Week Parameters ? Freq?enc? -
<br />0 pH, alkalinity, sulfate, Ca, Fe, K, Mg, Na, Al, As, Zn
<br />1 pH, alkalinity, sulfate, Ca, Fe, K, Mg, Na, Al, As, Zn
<br />2-20 pH, alkalinity, sulfate, Ca, Fe, K, Mg, Na Every 2 weeks
<br />2-20 Al, As, Zn Every 4 weeks
<br />20-52 H, alkalinity, sulfate, Ca, Fe, K, Mg, Na Every 4 weeks
<br />20-52 Al, As, Zn Every.8 weeks
<br />52+ H, alkalinity, sulfate, Ca, Fe, K, Mg, Na, Al, As, Zn Every 8 weeks
<br />Response #18
<br />While Wildcat Mining will commit to conducting a humidity cell test (ASTM D-5744-7),
<br />Wildcat Mining respectfully submits the need to prevent disposal of tailings underground
<br />based on readily available whole rock and water quality (including the fact historical
<br />mining activities have not adversely impacted water) is not technically iustified. See
<br />Exhibit T (Environmental Protection Plan) for supporting information. Within 60 days
<br />and as approved by DRMS, Wildcat Mining will initiate the humidity cell test.
<br />Adequacy Issue #19
<br />Attachment T-5, Surface Water Sampling Results. The Applicant should make the following
<br />revisions to the surface water sampling and monitoring plan:
<br />1 - Add to dissolved analyte list: Aluminum, Iron
<br />2 - Add to total recoverable analyte list:
<br />A - Molybdenum
<br />B - Cyanide (the WQCC regulations are in terms of free cyanide, but the operator may
<br />analyze for WAD cyanide if they choose.)
<br />C - Total organic carbon
<br />3 - Switch from dissolved to total recoverable: Barium, Beryllium, Boron
<br />Response #19
<br />The requested analytes will be added to the surface and to any future groundwater
<br />monitoring plan The analvtes will be added to the fifth sampling event which will occur in
<br />May 2011.
<br />May Day Idaho Mine Complex 112(d) Permit Application
<br />Revised: April 14, 2011
<br />8
|