Laserfiche WebLink
Response to Geochemistry Review - May Day Conversion CN-1 <br />File No. M-1981-185 <br />underground disposal option, the operator should commence the test as soon as possible. The <br />Division will not allow any permanent underground disposal of tailings until at least one year's <br />worth of data have been produced from the humidity cell test. <br />The following table provides the humidity test protocols for analytes and frequency of analyses. <br />The operator must refer to ASMT method D5744-07 for the required testing methodology. As <br />this is a standardized ASTM test, there are certified laboratories available that have the capability <br />and expertise to conduct this type of test. <br />Week Parameters ? Freq?enc? - <br />0 pH, alkalinity, sulfate, Ca, Fe, K, Mg, Na, Al, As, Zn <br />1 pH, alkalinity, sulfate, Ca, Fe, K, Mg, Na, Al, As, Zn <br />2-20 pH, alkalinity, sulfate, Ca, Fe, K, Mg, Na Every 2 weeks <br />2-20 Al, As, Zn Every 4 weeks <br />20-52 H, alkalinity, sulfate, Ca, Fe, K, Mg, Na Every 4 weeks <br />20-52 Al, As, Zn Every.8 weeks <br />52+ H, alkalinity, sulfate, Ca, Fe, K, Mg, Na, Al, As, Zn Every 8 weeks <br />Response #18 <br />While Wildcat Mining will commit to conducting a humidity cell test (ASTM D-5744-7), <br />Wildcat Mining respectfully submits the need to prevent disposal of tailings underground <br />based on readily available whole rock and water quality (including the fact historical <br />mining activities have not adversely impacted water) is not technically iustified. See <br />Exhibit T (Environmental Protection Plan) for supporting information. Within 60 days <br />and as approved by DRMS, Wildcat Mining will initiate the humidity cell test. <br />Adequacy Issue #19 <br />Attachment T-5, Surface Water Sampling Results. The Applicant should make the following <br />revisions to the surface water sampling and monitoring plan: <br />1 - Add to dissolved analyte list: Aluminum, Iron <br />2 - Add to total recoverable analyte list: <br />A - Molybdenum <br />B - Cyanide (the WQCC regulations are in terms of free cyanide, but the operator may <br />analyze for WAD cyanide if they choose.) <br />C - Total organic carbon <br />3 - Switch from dissolved to total recoverable: Barium, Beryllium, Boron <br />Response #19 <br />The requested analytes will be added to the surface and to any future groundwater <br />monitoring plan The analvtes will be added to the fifth sampling event which will occur in <br />May 2011. <br />May Day Idaho Mine Complex 112(d) Permit Application <br />Revised: April 14, 2011 <br />8