Laserfiche WebLink
MR-418 Calculations <br /> Structure: C5E-3-24"HDPE-#17 <br /> Manning's Coefficient(n) 0.012 <br /> Inside Diameter(in) 19.5 <br /> Radius(in) 9.75 <br /> Area(ft) 2.07 <br /> Hydraulic Radius(ft.) 0.41 <br /> Slope(ft./ft.) 0.05 <br /> Maximum Flow(cfs) 31.56 <br /> Design Discharge(cfs) 21.6 <br /> Combined Flow 24.35 <br /> (C5E-3 Design Flow+C5E-25 Design Flow) <br /> Maximum Flow>Combined Flow? Yes <br /> Structure: C5E-2-24"HDPE-Stand Alone#1 <br /> Manning's Coefficient(n) 0.012 <br /> Inside Diameter(in) 19.5 <br /> Radius(in) 9.75 <br /> Area(ft) 2.07 <br /> Hydraulic Radius(ft.) 0.41 <br /> Slope(ft./ft.) 0.03 <br /> Maximum Flow(cfs) 24.45 <br /> Design Discharge(cfs) 21.6 <br /> Combined Flow 24.35 <br /> (C5E-3100 Year+C5E-25 Design Flow) <br /> Maximum Flow>Combined Flow? Yes <br /> 5 of 5 8/23/2016 <br />