Laserfiche WebLink
MR-418 Calculations <br /> Structure: C5E-7-30"HDPE-Stand Alone#1 <br /> Manning's Coefficient(n) 0.024 <br /> Inside Diameter(in) 24.3 <br /> Radius(in) 12.15 <br /> Area(ft) 3.22 <br /> Hydraulic Radius(ft.) 0.51 <br /> Slope(ft./ft.) 0.05 <br /> Maximum Flow(cfs) 28.38 <br /> Design Discharge(cfs) 13.7 <br /> Combined Flow 16.45 <br /> (C5E-7 Design Flow+C5E-25 Design Flow) <br /> Maximum Flow>Combined Flow? Yes <br /> Structure: D5E-4-#6 <br /> w/Freeboard <br /> (ft.) <br /> Manning's Coefficient(n) 0.017 <br /> Top Width(T) 4.21 <br /> Bottom Width(b) 0.00 <br /> Depth(h) 1.05 <br /> z(ft.) 2.00 <br /> Area(ft) 2.21 <br /> Wetted Perimeter(ft.) 4.70 <br /> Hydraulic Radius(ft.) 0.47 <br /> Slope(ft./ft.) 0.11 <br /> Maximum Flow(cfs) 38.82 <br /> Design Discharge(cfs) 15.95 <br /> Combined Flow 18.70 <br /> (D5E-4 Design Flow+C5E-25 Design Flow) <br /> Maximum Flow>Combined Flow? Yes <br /> 2 of 5 8/23/2016 <br />