My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-11-15_REVISION - M1980244 (181)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2010-11-15_REVISION - M1980244 (181)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:52:27 PM
Creation date
12/1/2010 6:47:57 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REVISION
Doc Date
11/15/2010
Doc Name
QA Monitoring and Test Results- 2010, VOL.1 Cover & table of contents
From
CC&V
To
DRMS
Type & Sequence
AM9
Email Name
BMK
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ameO <br />• Permeability (ASTM D5084, Method D); <br />• In-place density testing (ASTM D2922); <br />• Soil description (ASTM D2488); <br />• Bulk specific gravity (ASTM C127; and <br />• Point Load Strength Index (ASTM D5731, Method D). <br />0 <br />AMEC conducted appropriate tests as required by the specifications for UF, SSF, CSB, SF, <br />SLF, LVSCF, DCF, and SDCF. <br />The laboratory test results are summarized in Tables 6 through 12 and presented in <br />Appendix H. <br />4.1.1 Grain Size Distribution <br />AMEC analyzed the grain size distribution (gradation) of samples of UF, SSF, SF, SLF, <br />LVSCF, DCF, and CSB. The results of gradation analyses are presented in Appendix H-1 <br />and summarized in Tables 6 through 12. <br />AMEC performed three CQA gradation of UF. The testing frequency (approximately one <br />test per 59 cubic yards) exceeded the minimum specified testing frequency of one test per <br />5,000 cubic yards. The CQA gradation of OF met project specifications. The OF CQA <br />gradation results are presented in Appendix H-1 and summarized in Table 6. <br />AMEC performed four CQA gradation of the SSF. The testing frequency (approximately one <br />test per 221 cubic yards) exceeded the minimum specified testing frequency of one test per <br />50,000 cubic yards. The CQA gradations of SSF met project specifications. The SSF CQA <br />gradation results are presented in Appendix H-1 and summarized in Table 7. <br />AMEC performed fifty-three CQA gradations of SF. The testing frequency (approximately <br />one test per 47,415 cubic yards) exceeded the minimum specified testing frequency of one <br />test per 50,000 cubic yards. The CQA gradations performed on SF met project <br />AMEC Earth & Environmental, Inc. <br />2000 S. Colorado Blvd 2-1000 <br />Denver, CO 80222 <br />Tel 303-935-6505 <br />Fax 303-935-6575 <br />www.amec.com <br />26