Laserfiche WebLink
CYPRUS CLIMAX MINE STORM WATER MANAGEMENT PLAN <br /> BMP IDENTIFICATION <br /> (SECTION 2.3.1) <br /> Date of Identification: 6/20/96 By: W. W. Wheeler and Associates, Inc. <br /> Evaluation Deadline Date: <br /> Key Number: A 06480N, -9940E) (Plate No. I) <br /> Description: Dam 4 Seep Water Collection/Pump Station <br /> Type of Character of Potential Pollutant: Seepage through embankment. Potential contact with mine tailing waste. <br /> BMP Detailed Control, Practice or Activity <br /> Good Housekeeping <br /> Preventive Pump equipment. Maintain pumping equipment and pump discharge pipeline. <br /> Maintenance <br /> Inspections Inspect pump equipment and drainage separation between dam toe and seepwater sump. <br /> Spill Prevention Manage water levels in existing detention sumps. <br /> or Containment <br /> Sediment and <br /> Erosion Control <br /> Management Separation of toe seepage and storm water. <br /> of Runoff <br /> Other Specific Regrade area to eliminate all but seepage from toe of embankment. <br /> Activities <br />