My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-02-02_REVISION - M1979181
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1979181
>
2010-02-02_REVISION - M1979181
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2021 6:03:06 PM
Creation date
3/16/2010 10:24:37 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1979181
IBM Index Class Name
REVISION
Doc Date
2/2/2010
Doc Name
Solids analysis 2008-2009
From
Grayling LLC
To
DRMS
Type & Sequence
TR2
Email Name
WHE
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. 71z_'1'1n1-1 2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Mount Sneffels Mining Company, LLC ACZ Project ID: L79933 <br /> <br />L79933-02 WG276474 Aluminum (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG276402 Aluminum, total (3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level. The recovery of the associated control sample (LCS <br /> or LFB) was acceptable. <br />WG276458 Antimony (1312) M6020 ICP-MS RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< IN MDL). <br />WG276433 Antimony, total (3050) M6020 ICP-MS M2 Matrix spike recovery was low, the recovery of the <br /> associated control sample (LCS or LFB) was acceptable. <br />WG276458 Arsenic (1312) M6020 ICP-MS RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG276474 Barium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG276463 Barium, total (3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level. The recovery of the associated control sample (LCS <br /> or LFB) was acceptable. <br />WG276474 Beryllium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< IN MDL). <br />WG276529 Cadmium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />Chromium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG276402 Chromium, total (3050) M6010B ICP M1 Matrix spike recovery was high, the recovery of the <br /> associated control sample (LCS or LFB) was acceptable. <br /> M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br /> because the sample concentration was less than 50 times <br /> the MDL. <br />WG276474 Cobalt (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG276529 Copper (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG276474 Iron (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG276463 Iron, total (3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level. The recovery of the associated control sample (LCS <br /> or LFB) was acceptable. <br />WG276458 Lead (1312) M6020 ICP-MS RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< IN MDL). <br />WG276433 Lead, total (3050) M6020 ICP-MS MA Recovery for either the spike or spike duplicate was outside <br /> of the acceptance limits; the RPD was within the <br /> acceptance limits. <br />WG276474 Magnesium (1312) M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br /> because the sample concentration was less than 50 times <br /> the MDL. <br />WG276529 Manganese (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br /> validation because the sample concentration is too low for <br /> accurate evaluation (< 10x MDL). <br />WG276402 Manganese, total (3050) M6010B ICP M3 The spike recovery value is unusable since the analyte <br /> concentration in the sample is disproportionate to the spike <br /> level. The recovery of the associated control sample (LCS <br /> or LFB) was acceptable. <br /> M6010B ICP ZH Serial Dilution exceeded the acceptance criteria. Matrix <br /> interference [physical or chemical) is suspected. <br />REPAD.15.06.05.01 <br />Page 32 of 39
The URL can be used to link to this page