October 2004 -19- 043 -2170 <br />Golder perfonmed six CQA gradations of SF. The testing frequency (approximately one test per <br />20,842 cubic yards) exceeded the minimum specified testing frequency of one test per 50,000 cubic <br />yards. The CQA gradations performed on SF met project specifications. The SF CQA gradation <br />results are ,presented in Appendix I -1 and summarized in Table 9. <br />Golder performed 21 CQA gradations of SLF. The testing frequency (approximately one test per <br />4,592 cubic yards) exceeded the minimum specified testing frequency of one test per 5,000 cubic <br />yards. The CQA gradations performed on SLF met project specifications. The SLF CQA gradation <br />results are presented in Appendix 1 -1 and summarized in Table 10. <br />Golder performed ten CQA gradations of DCF. The testing frequency (approximately one test per <br />19,290 cubic yards) exceeded the minimum specified testing frequency of one test per 20,000 cubic <br />yards. The DCF CQA gradations met project specifications, and the results are presented in <br />Appendix I -1 and summarized in Table 11. <br />Golder performed two CQA gradations of FSB. No testing frequency was identified in the CQA plan <br />for this material. The CQA gradation performed on FSB met project specifications. The FSB <br />gradation results are presented in Appendix I -1 and summarized in Table 12. <br />4.1.2 Moisture Content <br />Golder measured oven moisture contents of UF, SSF, FSB, LDF, PBM, SF, SLF, and DCF as part of <br />the CQA program. Moisture content data is presented in Appendix 1 -1. <br />4.1.3 Atterberg Limits <br />Golder performed Atterberg limit testing of all fill materials. All fill materials, with the exception of <br />SF and SLF were non- plastic. The SLF, SF, UF, LDF, PBM, SSF, DCF, and FSB samples tested met <br />project specifications for Atterberg Limits. <br />The SLF testing frequency (approximately one test per 4,592 cubic yards for SLF) exceeded the <br />minimum specified testing frequency. The plasticity index of the CQA SLF samples ranged from 21 <br />to 32, meeting the project specification of plasticity index greater than or equal to 10. Atterbe o limit <br />test results for SLF are presented in Appendix I -1 and summarized in Table 10. <br />61411t70 "0\Cett- 4 QAP►No-IGOM=79.WO&124&C rtrbtVGdu Golder Associates <br />