Laserfiche WebLink
consequences). If during Phase I or 2 construction of the CRDA, shallow failures are observed on <br />the face of the fill with any frequency, the proposed slope configuration should be modified <br />(1lattened) to prevent such failures from occurring in the future phases <br />Please provide additional language in Section2.05 of the permit to address actions that will be taken, <br />should there be shallow slope failures observed on the face of the CRDA fill <br />Response: If shallow localized failures are observed on the face of the fill during the early sequences <br />of construction, material (typically moisture-holding fines) will be removed from the area of the failure <br />and replaced with compacted coarse material. If such failures occur with any frequency, the slope <br />configuration may be modified (flattened) or other measures implemented to minimize the potential for <br />future failures. Section 2.05 has been revised to address repair of minor slope failures.