2009-10-05_REVISION - C1996083 (2)
DRMS
>
Day Forward
>
Revision
>
Coal
>
C1996083
>
2009-10-05_REVISION - C1996083 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:56:00 PM
Creation date
10/6/2009 11:30:28 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1996083
IBM Index Class Name
REVISION
Doc Date
10/5/2009
Doc Name
1st Adequacy Review
From
J.E. Stover & Associates, Inc
To
DRMS
Type & Sequence
TR64
Email Name
JJD
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J. J. Dudash -5- October 01, 2009 <br />BRL - The Division is correct, there will be an increase of approximately 0.87 <br />acres to the disturbed area of the mine. The revised Technical Revision <br />application is attached. In addition, please see the revised disturbed area <br />boundary as shown on Map 18. <br />15. DRMS - Based on a review of Volume IX, Figure 1, Coal Mine Waste Disposal <br />Area, the horizontal scale of the inset cross-section B-B' has been changed and <br />appears to be in error. The horizontal scale on the currently approved figure is <br />shown as 40 feet/inch. The horizontal scale on the revised figure is shown as 100 <br />feet/inch. This changes the length of the cross section from 600 feet to 1,500 <br />feet. To further complicate the issue, based on the scale of the small map <br />showing the gob piles, at 200 feet/inch, cross-section B-B' is only 300 feet long (1 <br />-X2 inches). Based on the 2:1 slope indicator on the "Proposed Ground Surface" <br />line for cross-section B-B", it appears as though the correct horizontal scale <br />should be 20 feet/inch. Please check the B-B' cross-section line and detail and <br />correct the scale as necessary. <br />BRL - The scaled has been corrected, please see revised Figure 1. <br />16. DRMS - Based on a review of Volume IX, Figure 1, Coal Mine Waste Disposal <br />Area, the horizontal scale of the inset cross-section C-C' has been changed and <br />appears to be in error. The horizontal scale on the currently approved figure is <br />shown as 40 feet/inch. The horizontal scale on the revised figure is shown as 100 <br />feet/inch. This changes the length of the cross section from 800 feet to 2,000 <br />feet. To further complicate the issue, based on the scale of the small map <br />showing the gob piles, at 200 feet/inch, cross-section B-B' is only 400 feet long (2 <br />inches). Based on the 2:1 slope indicator on the "Proposed Ground Surface" line <br />for cross-section C-C', it appears as though the correct horizontal scale should <br />be 20 feet/inch. Please check the C-C' cross-section line and detail and correct <br />the scale as necessary. <br />BRL - The scale has been corrected, please see revised Figure 1. <br />17. DRMS - In the table labeled "Appendix B" on proposed page App-B 9, there are <br />several entries for peak flows that do not correspond to those listed in the current <br />or proposed designs. These peak flow entries are for ditches F1, F2, F9, F11, <br />F13, F14, F16, F17, F18, East Diversion, West Diversion #1 and culvert F2. <br />Except for ditch F2, it appears that the designs for these ditches and one culvert <br />were revised but not included in TR-64. Please provide the revised designs or <br />revise proposed Appendix B accordingly. <br />BRL - F1 has been revised and the structure detail should have been included. <br />Please see structure detail for Ditch F1 on page App B-12. F2 has been revised, <br />and the peak flow shown on page App B-9 was apparently a typo, and has been <br />corrected. F9 has been revised and the structure detail should have been <br />included. Please see structure detail for Ditch F9 on page App B-20. F11 has <br />been revised and the structure detail should have been included. Please see <br />structure detail for Ditch F11 on page App B-22. F13 has been revised and the