Laserfiche WebLink
Iron (mg/1) 0.9 2.38 <br />Jul 2008 <br /> Pond Hillside <br />Total Dissolved Solids (mg/1) 4312 3629 <br />Total Suspended Solids (mg/1) 24 22 <br />Iron (mg/1) 0.83 2.04 <br />August 2008 <br /> Pond Hillside <br />Total Dissolved Solids (mg/1) 3845 2775 <br />Total Suspended Solids (mg/1) 30 85 <br />Iron (mg/1) 1.17 2.85 <br />September 2008 <br /> Pond Hillside <br />Total Dissolved Solids (mg/1) 3217 2890 <br />Total Suspended Solids (mg/1) 22 16 <br />Iron (mg/1) 0.86 0.75 <br />October 2008 <br /> Pond Hillside <br />Total Dissolved Solids (mg/1) 3634 2969 <br />Total Suspended Solids (mg/1) 57 49 <br />Iron (mg/1) 0.51 1.72 <br />November 2008 <br /> Pond Hillside <br />Total Dissolved Solids (mg/1) 3574 3277 <br />Total Suspended Solids (mg/1) 15 14 <br />Iron (mg/1) 0.78 1.04 <br />December 2008 <br /> Pond Hillside <br />Total Dissolved Solids (mg/1) 3388 2996 <br />Total Suspended Solids (mg/1) 26 26 <br />Iron (mg/1) 0.71 1.27 <br />There does not appear to be any trend in the data presented above. The water <br />from the hillside is suitable to discharge directly to the river without treatment. Iron <br />values in the hillside water are higher than the pond water. Most of the hillside analyses <br />were within discharge limitations. The hillside water also passed the four WET tests <br />performed during the year. <br />-6-