My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-04-15_REVISION - M1980244 (308)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1980244
>
2008-04-15_REVISION - M1980244 (308)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:52:12 PM
Creation date
5/12/2008 10:30:22 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REVISION
Doc Date
4/15/2008
Doc Name
VOL VII APP 12 Appendix G Engineering Evaluation
From
CC & V
To
DRMS
Type & Sequence
AM9
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br />CC&V TANK VISUAL INSPECTION AND INTEGRITY TESTING (Page 1 of 2) <br />• <br />Tank No. Tank /Container Volume Contents of Tank or <br />or Container Material Tank Units Container Visual Inspection Integrity Testing' Location or Comment <br />Tanks and Containers INSIDE the Ironclad Facili <br />Rock Drill Oil <br />Compressor Oil (Tegra ISO 68) <br />Motor Oil SAE 50 <br />Antifreeze (Ethylene Glycol) <br />Drive Train Oil 10 Weight <br />Duratec #DT875 <br />Used Oil <br />Drive Train Oil 30 Weight <br />Hydraulic Oil 30 Weight <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Ironclad Facility -Old Truck Shop Oil Room <br />Ironclad Facility -Old Truck Shop Oil Room <br />Ironclad Facility -Old Truck Shop Oil Room <br />Ironclad Facility -Old Truck Shop Oil Room <br />Ironclad Facility -Old Truck Shop Oil Room <br />Ironclad Facility -Old Truck Shop Oil Room <br />Ironclad Facility -Old Truck Shop Oil Room <br />Ironclad Facility -Old Truck Shop Oil Room <br />Ironclad Facility -Old Truck Shop Oil Room <br />OTS-1 Cylindrical Steel Tank 658 gal <br />OTS-2 Cylindrical Steel Tank 658 gal <br />OTS-3 Cylindrical Steel Tank 1,248 gal- <br />OTS-4 Cylindrical Steel Tank 1,248 gal <br />OTS-5 Cylindrical Steel Tank 4,888 gal <br />OTS-6 Cylindrical Steel Tank 4,888 gal <br />OTS-7 Cylindrical Steel Tank 11,844 gal <br />OTS-9 Cylindrical Steel Tank 658 gal <br />OTS-10 Cylindrical Steel Tank 658 gal <br />Tanks and Containers OUTSIDE the Ironclad Facility <br />OTS-130 Steel Cylindrical Tank 353 gal <br />Tanks and Containers INSIDE the New Truck Sho <br />NTS-1 Steel Cylindrical Tank 12,000 gal <br />NTS-2 Steel Cylindrical Tank 6,000 gal <br />NTS-3 Steel Cylindrical Tank 6,000 gal <br />NTS-4 Steel Cylindrical Tank 6,000 gal <br />NTS-5 Steel Cylindrical Tank 6,000 gal <br />NTS-6 Steel Cylindrical Tank 3,000 gal <br />NTS-15 Rectangular Steel Tank 500 gal <br />NTS-16 Rectangular Steel Tank 850 gal <br />(feeder tank to burner) <br />Diesel Fuel <br />Used Oil <br />Hydraulic Oil 10 Weight <br />Motor Oil 50 Weight <br />Motor OII 15W30 <br />Gear Oil 80W90 <br />Antifreeze <br />Oil from Oil/Water Separator <br />for Burning in Heaters <br />Oil from Oil/Water Separator <br />for Burning in Heaters <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Monthly <br />Every 5 Years -Start 2010 Ironclad -Behind Bldg Housing Generator <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />Every 5 Years -Start 2010 <br />New Truck Shop Oil Room <br />New Truck Shop Oil Room <br />New Truck Shop Oil Room <br />New Truck Shop Oil Room <br />New Truck Shop Oil Room <br />New Truck Shop Oil Room <br />New Truck Shop Heater/Burner Room <br />New Truck Shop Heater/Burner Room <br />'40 CFR Part 112.7(d) requires that for bulk storage containers, periodic integrity testing of containers and leak testing of valves and piping must be conducted. Steel Tank Institute <br /> SP001-03 <br />Inspection of Shop Fabricated ASTs will serve as the reference method for testing. American Petroleum Institute 653 may also be used for tanks and API Standard 570 may be used for piping. <br />Appropriiate integrity testing may be done by a CC&V employee providing the employee has received training by the company that manufactures the device used to conduct the testing. For <br /> example, <br />if the CC&V employee uses a model "25DL plus" by Olympus to conduct ultrasonic tests, then he/she must verify in writing that he/she has completed a training course by Olympus or has <br />been instructed by a competent instructor in the proper use of the equipment. This written record of training must be kept with the current SPCC plan. Previous training and experience <br /> can <br />suffice if the employee documents use of the equipment and signs a statement that he/she is competent in the use of the device in question. This record must be kept with the current <br /> SPCC plan. <br />It is the opinion of the certifying engineer that this procedure of allowing a qualified CC&V employee to conduct the testing is "equivalent environmental protection" under the SPCC <br /> regulations at <br />40 CFR Part 112. Prepared by Michael D. Ellis, P.E. 4-7-03, revised 12-5-07 <br />Tank Inspection September 25, 2006 <br />EMS: AGANA/CCV Printed Copies are Uncontrolled Doc. # E-006 <br />S:\4010-00055 CC & V 112(d) Permit Application\ERP, SPCC, FMP\APP-J-Tank Testing-5-06 Revision 03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.