My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2003-02-07_GENERAL DOCUMENTS - M1977208
DRMS
>
Day Forward
>
General Documents
>
Minerals
>
M1977208
>
2003-02-07_GENERAL DOCUMENTS - M1977208
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 2:18:47 PM
Creation date
4/14/2008 10:12:45 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977208
IBM Index Class Name
GENERAL DOCUMENTS
Doc Date
2/7/2003
Doc Name
Samples from before and after the test tire burn
From
Banks and Gesso, LLC
To
DRMS
Email Name
ESC
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lot #: D2L050313 <br />SPLP GC/MS Semi-Volatile Organic Analvsis, Method SW-846 8270C/1312 <br />No anomalies were observed. <br />GC Semi-Volatile Diesel Range Organic Analvsis Method SW-846 8015B <br />No anomalies were observed. <br />SPLP iV[etals Analvsis, Method SW-846 6010B/1312 <br />Boron, magnesium, cobalt and silicon were detected in the Method Blank at concentrations below the <br />reporting limits but above the method detection limits. The Method Blank is still considered under <br />control. Associated positive sample results are qualified with a "J" on the analytical report. <br />Calcium was detected in the Method Blank at a concentration above the reporting limit. Since the <br />concentration of calcium in the associated samples was greater than 10 times the concentration in the <br />blank the data was accepted. <br />The MS and MSD performed on sample SAMPLE 2 demonstrated recoveries and /or 1ZPDs outside <br />the established control limits for cadmium, chromium, manganese, selenium and strontium (prep <br />batch 2347390). Since the LSC and method blank were in control, no corrective action was taken and <br />the anomalies were attributed to matrix interference. <br />SPLP Mercury Analvsis, Method SW-846 7470A <br />Mercury was detected in the Method Blank at a concentration below the reporting limit but above the <br />method detection limit. The Method Blank is still considered under control. All associated positive <br />sample results are qualified with a "J" on the analytical report. <br />The recoveries and calculated RPD's for the MS and MSD performed on sample SAMPLE 1 were <br />within established control limits. <br />General Che~nistry -Various Methods (analyzed on the SPLP leachate of each sample) <br />Specific conductance and TOC were detected in the Method Blanks at concentrations below the <br />reporting limits but above the method detection limits. Associated positive sample results are <br />qualified with a "J" on the analytical report. <br />The MS and/or MSD performed on sample SAMPLE 1 SPLP LEACHATE demonstrated recoveries <br />and /or 1ZPDs outside the established control limits for chloride and nitrate. Since the LSC and <br />method blank were in control, no corrective action was taken and the anomalies were attributed to <br />matrix interference. <br />SPLP Gross Alpha/Beta Radiochemistry Analvsis, 1Vlethod 900.0 <br />No anomalies were observed. <br />3 <br />