My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-03-10_REPORT - C1981022
DRMS
>
Day Forward
>
Report
>
Coal
>
C1981022
>
2008-03-10_REPORT - C1981022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:24:40 PM
Creation date
3/10/2008 2:53:16 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981022
IBM Index Class Name
REPORT
Doc Date
3/10/2008
Doc Name
2007 Annual Hydrology Report
From
Oxbow Mining, LLC
To
DRMS
Annual Report Year
2007
Permit Index Doc Type
Hydrology Report
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.2 Monitoring Information <br />The hydrologic monitoring parameters and the schedules for the hydrologic monitoring programs <br />are presented in Section 2. The monitoring sites, parameters and schedules have evolved over <br />time as the facility has evolved and changed. The current monitoring program was substantially <br />modified in 2001 I~er Permit Revision PR-04 and further modified in TR-47 in 2004. The <br />current monitoring; program can be found in Exhibit 2.05-E7 -Hydrologic Monitoring Plan of <br />the CDRMS permit. <br />Field parameters for groundwater are depth to water level, pH, conductivity, and temperature. <br />Field parameters for surface water are flow, pH, conductivity, and temperature. Equipment and <br />methods used to measure the field parameters include: <br />• Depth to eater level - A cable marked in increments is lowered into the groundwater <br />monitoring; well until electrical continuity is reached at the water surface. <br />• pH - A Cole Parmer pH Testr 3 pocket-size tester is used to measure the pH of a water <br />sample. Published specifications for the pH Testr 3 are range: pH - 1.0 to 15.0, <br />resolution: 1.0 pH, accuracy: +\- 0.1 pH, automatic temperature compensation: 0 to 50 <br />degrees C, calibration points 1, 2, or 3. The pH tester is calibrated prior to sampling <br />events usi~ig the 2 point method. The expected pH is bracketed by the pH of the <br />calibration solutions. In most cases the pH tester is calibrated to 7 and 10 which brackets <br />all of the current monitoring results. If an expected pH is less than 7, the pH tester can be <br />calibrated at 4 and 7. <br />• Conductivity - A Cole Parmer pocket-size TDS Testr 3 or TDS Testr 4 is used to measure <br />the conductivity of a water sample. Published specifications for the TDS Testr 3 are <br />range: 0 to 1990 uS, resolution 10 uS, accuracy: +\- 2% full scale, automatic temperature <br />compensation: 0 to 50 degrees C, calibration with standard solution. Published <br />specifications for the TDS Testr 4 are range: 0 to 19.90 mS, resolution: 0.1 mS, accuracy: <br />+\- 2% fulll scale, automatic temperature compensation: 0 to 50 degrees C, calibration <br />with standard solution. <br />• Temperature - A standard mercury thermometer that measures temperature in degrees <br />Celsius is used. <br />• Flow -Tree flow is measured in one of four different ways. The first method is to utilize <br />a known culvert size combined with the depth of flow and the velocity determined by <br />measuring; the time it takes a floating object to travel a known distance. The second <br />method is. to time flow into a bucket of known size. The third is to measure the length, <br />width, depth, and the velocity of a stream of water or sum the flows measured in <br />segments of a larger stream of water. The fourth way, used to find the flow of the North <br />Fork of the Gunnison, is obtained from the nearby USGS gauging station. <br />• Dissolved Oxygen - An EXTECH Mode1407510 Dissolved Oxygen Meter is used to <br />measure ciissolved oxygen with a remote sensor also containing a thermister for <br />measuring temperature. The DO range is 0.0 -19.9 mg/1 + 0.4 mg/1 with 0.1 mg/1 <br />resolutio~i. Before use, the meter is calibrated according to the meter calibration <br />procedure. <br />Historically, water samples from groundwater wells H-10 and B-6 had been taken with a bailer <br />that has a restricl:ed inlet. The bailer is weighted so it sinks to the bottom of the well when it is <br />2 <br />