My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REP16533
DRMS
>
Back File Migration
>
Report
>
REP16533
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 11:45:48 PM
Creation date
11/27/2007 1:54:45 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1980007
IBM Index Class Name
Report
Doc Date
8/23/1996
Doc Name
REVIEW OF 1993 & 1994 ANNUAL HYDROLOGY REPORTS WEST ELK MINE PN C-80-007
From
DMG
To
MOUNTAIN COAL CO
Permit Index Doc Type
HYDROLOGY REPORT
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Christine Johnston <br />Mountain Coal Company <br />Page 10 <br />August 23, 1996 <br />the water year (see Appendix F and Appendix H). This makes the report <br />more compact and reduces the number of tables presented in the report. The <br />Division recommends that this should be done with surface water baseline <br />values as well, in future AHRs. Please revise the Table of Contents under <br />Appendices, Appendix E only contains a comparison of baseline minimum and <br />maximum values for surface water. As previously stated, a comparison of <br />baseline values for spring water and groundwater were provided in Appendix <br />F and Appendix H, respectively. <br />11. The following required analytical data are missing from the groundwater <br />monitoring data in Appendix H, Table H-1. <br />• Field parameters for well SG-1 were not provided. <br />• Mn is missing for GP-1. <br />• No samples were collected from wells GP-3 and GP-4 throughout WY <br />1994. <br />• Fe and Mn are missing for one of the three required sample rounds <br />for well SOM-16-H. ' <br />• pH and specific conductance are missing for all three required sample <br />rounds and TSS is only provided for one of the three required sample <br />rounds for well SOM-C-72-H. <br />• pH, specific conductance, and TSS are missing for all three sample <br />windows for well SOM-129-H. <br />• pH, specific conductance, and TSS are missing for all three sample <br />windows for well SOM-128-H. <br />Please provide an explanation why these required data were not collected or <br />if they are available provide them in a revised report page. If sample <br />collection is a problem for various wells, the Division recommends <br />redeveloping certain wells (SG-1, GP-5, SW-2, SW-5, and SW-6) to remove <br />the silt/mud and increase grotmdwater flow into the well. <br />12. There are two explanations and two footnotes for footnote 1 for Appendix H, <br />Table H-1. Please clarify and provide revised report pages. <br />
The URL can be used to link to this page