My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REP00257
DRMS
>
Back File Migration
>
Report
>
REP00257
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 11:29:11 PM
Creation date
11/26/2007 9:36:57 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1999002
IBM Index Class Name
Report
Doc Date
6/23/2003
Doc Name
Cavity Characterization Plan
From
American Soda LLP
To
DMG
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
224
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
December 23, 1991 Page C-!Z <br />• carbon copy will be retained by the samplers. Chain-of-custody will be maintained until final <br />disposition of the samples by the laboratory. <br />C.6 INSTRUMENT CALIBRATION <br />C.6.1 pH Meter <br />The pH meter must be calibrated before taking any readings of samples and if erroneous <br />readings are suspected. Calibration and operation of the pH meter should follow the manufacturer's <br />specific instructions. In general, calibration is done by adjusting the meter with standard buffers that <br />bracket the expected pH of field water. Calibration will consist of the following general procedures: <br />Adjust the reading of the pH meter with the electrode placed in the pH 7 buffer by <br />using the calibration knob. Rinse the electrode with distilled water between buffer <br />adjustments. <br />Adjust the reading ofthe meter with the electrode placed in the pH 10 buffer with the <br />slope (or temperature) knob. <br />• ~ Repeat steps i and 2 untii the meter gives acceptable readings (t0.1 pH unit} for all <br />the buffers used for calibration. <br />Note: Always use the same electrode for measurements that was used in the calibration. <br />Recalibrate the meter if the electrode is replaced. Also, the temperature setting on the pH meter <br />often does not match the sample temperature after calibration. The pH readings will still be accurate <br />in these cases, provided that the response to the buffers is correct. <br />Record the time and temperature in the field notebook whenever the pH meter is calibrated. <br />When recording pH values from a sample, check pH meter and recalibrate (as necessary) if sample <br />pH values are significantly different from previous values. <br />C.6.2 Conductivity Meter <br />The temperature-compensated conductivity meter must be calibrated before taking field <br />measurements. Record time, temperature, and instrument response in the field notebook. <br />Calibration is done by noting the response of [he meter to several standard conductivity solutions <br />which bracket the values expected to be measured in the Held. Standards of 100, 1,000, and ] 0,000 <br />• should be adequate for the samples expected. If the instrument has a calibration adjustment, set the <br />response to match the standards. Otherwise, simply record the instrument response to each stmrdard <br />in the field notebook. <br />Agapito Associates, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.