Laserfiche WebLink
• <br />-24- <br />APPENDIX A <br />GEX Colorado, Inc. <br />Compression Test Results <br />Specimen Length Diameter Confining Failure Corrected Failure <br />~ <br />- Ident. in) in) Pressure{psi) Load lb) Strength(psi) 2 x 1 Mode <br />„ 2E 1 3.895 2.135 0 9900 2770 2730 SC <br />f 2E 2 3.514 2.125 205 22000 6200 6060 MSC <br />i 2E 3 2.605 2.120 2000 39600 11140 10330 VSC <br />2E 4 2.544 2.120 820 36500 10310 9520 MSC <br />2E 5 3.477 2.114 1000 29700 8420 8200 SC <br />2E 6 3.936 2.120 410 32100 9080 8990 VSC <br />' 2E <br />1 7 3.544 2.119 590 24400 6900 6730 MSC <br />` 2E 8 3.814 2.118 0 9510 2700 2660 NSC <br />~ 3E 1 4.015 2.122 0 8800 2490 2470 SC <br />3E 2 4.202 2.122 820 37500 10570 10560 SC <br />._•3E 3 3.924 2.114 1000 34400 9760 9660 VSC <br />'' 3E 4 2.876 2.113 2000 45200 12800 12100 MSC <br />3E 5 3.595 2.113 215 30100 8570 8390 MSC <br />3E 6 3.964 2.114 425 25400 7220 7160 VSC <br />3E 7 3.926 2.114 595 32800 9320 9230 MSC <br />(~ 3E 8 3.968 2.118 0 11650 3310 3280 SC <br />~~ 3E 9F 1.925 1.500 0 4000 2260 2120 NSC <br />3ElOF 1.606 1.500 0 3550 2010 1810 NSC <br /> Platen diameter 2.160 <br /> NOTES: 2E samples from 2nd East Section, 10 + 00 station in beltline entry. <br />L . 3E samples from 3rd East Section, 5 + 00 station in 2nd right entry. <br /> F - samples from floor. <br />~~ SC - structural controlled failur e. <br /> NSC - no structural control of fai lure. <br /> MSC - minor structural control of failure. <br />. VSC - very structurally controlled failure. <br />