Laserfiche WebLink
<br /> -zi- <br />•' <br />TABLE 7. Pillar failure maximum subsidence predictions <br /> for Ute Water Co. surface facilities. <br /> Horizontal <br /> Pillar Maximum Maximum Strains Maximum <br />Oepth Width* Subsidence Tensile Compressive Tilt <br />_ <br />' ft ft ft ut) ut (' ) <br />200 12 1.50 4880 3820 70.9 <br />~ ~ 14 1.12 3640 2860 52.9 <br /> 15 0.99 3220 2520 46.8 <br />_ <br />' 16 0.88 2660 2240 41.6 <br /> 18 0.72 2340 1840 34.0 <br /> 20 0.60 1950 1530 28.4 <br />'- 30 0.32 1040 820 15.1 <br />250 12 1.85 4810 3770 69.9 <br /> 14 1.38 3590 2820 52.2 <br /> 15 1.22 3170 2490 46.1 <br />• 16 1.08 2810 2200 40.8 <br />' 18 0.87 2260 1780 32.9 <br /> 20 0.72 1870 1470 27.2 <br /> 30 0.37 960 760 14.0 <br />' 300 12 2.20 4770 3740 69.3 <br /> 14 1.64 3550 2790 51.7 <br />• 15 1.44 3120 2450 45.4 <br />r 16 1.28 2770 2180 40.3 <br /> 18 1.03 2230 1750 32.5 <br /> 20 0.85 1840 1440 26.8 <br /> 30 0.43 930 730 13.1 <br />*All pillars 80 ft. in length and 6.5 ft. in height. <br /> <br /> <br />