Laserfiche WebLink
• - 14 - <br />tests indicate that settlement should essentially occur during <br />construction. <br />(2) Footings should also be designed for a minimum dead load pressure <br />of 1,500 psf. <br />(3) If continuous foundation walls are used, they should be reinforced <br />to span an unsupported length of at least 10 feet. <br />(4) Excessively loose or soft pockets of soil found within the loaded <br />depth of the footings should be removed and the footings extended <br />to lower f(rm soil or the removed soli replaced compacted. <br />(5) All footings should be placed below frost depth. The anticipated <br />level of frost penetration Is 4 feet. <br />• - <br />LATERAL SOIL PRESSURES <br />' ~ Recommended design factors to assess lateral earth pressures <br />. against retaining structures are presented In the following tabulation. <br />Fill against footings, stem walls, and retaining structures should be <br />placed to a minimum 90$ of the ASTN D698 density to minimize total <br />active pressures. <br />Equivalent Active Pressures: <br />Undisturbed overburden Boll 45 psf/ft. <br />Compacted backfill 35 psf/ft. <br />Undisturbed claystone bedrock 35 psf/ft. <br />The above values consider no buildup of hydrostatic pressure. <br />Undnrdrains are discussed below. If underdralns are not provided, a <br />• <br />_.. .: ~ <br />