Laserfiche WebLink
The existing road and beginning segment will be left in place to serve the postmining land use. The topsoil windrowed <br />or stockpiled adjacent to the road will be seeded with the pastureland seed mixture. <br />• NMD Power Borehole <br />Upon completion of mining, and when the power borehole is no longer needed, the facilities will be removed and the site <br />reclaimed. Removal of the surface facilities will involve dismantling of surface structures, which includes the powerline, <br />transformer and pad, road and culvert, and building. After the facilities aze removed, the site will be regraded to blend <br />with the existing terrain, the stockpiled topsoil will be redistributed over the azea, and the power borehole pad and <br />reclaimed road segments will be seeded with the pastureland seed mixture. The entire road will be chisel-plowed after <br />removing the geotextile. <br />NW-Mains Ventilation Shaft and Thickener Underllow Project (1`ROl-39) <br />When the NW-Mains ventilation shaft and fan installation aze no longer needed to support ongoing or future mitring <br />operations, the associated surface facilities will be removed, the shaft will be plugged and sealed, and surface distwbance <br />azeas will be reclaimed. The fan equipment, buildings, powerline, and poles will be removed and reused at another <br />location, salvaged, or disposed of off-site. Concrete pads will be broken-up and foundations will be demolished to at <br />least 4 feet below grade, and the resulting concrete debris will be disposed of in the shaft opetring. The shaft collaz <br />concrete will also be broken up and disposed of in the shag opening, leaving an open space for the concrete decking, <br />concrete slab and backfill material to be placed in the shaft void. Shaft plugging and sealing will involve construction <br />and placement of apre-fabricated framework of steel support beams, steel composite decking and 4 inches of concrete to <br />be placed at the bottom of the shaft collar (approximately 20 feet below grade), which will rest on the lower shaft liner. <br />Once this is completed, a 24-inch thick reinforced concrete slab will be constructed over the previously placed slab and <br />decking. The concrete in this slab will also flow down and fill-in the annulaz space between the Cchannel and <br />surrounding strata as shown in Exhibit 26B, Section 3/S-1. This will effectively seal the plug at the interface of the plug <br />and lower shaft liner. Also, tie-ins will be placed around the periphery of the 24-inch slab to allow for tying-in the rebaz <br />• of the reinforced concrete slab. After this slab has cured, backfill material will be placed in the void. The backfill <br />material will be placed to within 6 inches of the surface, and the final 6 inches will be filled with topsoil. The plug <br />drawing is presented in Exhibit 26B, NW-Mains Ventilation Shaft Plug. <br />Following removal of structures and equipment and plugging and sealing of the shaft; road surfacing materials and <br />culverts will be removed and disposed of off-site; and the shag pad and access road disturbance azeas will be regraded to <br />reestablish effective drainage and blend with the surrounding terrain, Stockpiled and windrowed topsoil will then be <br />replaced on those disturbed areas where it was previously removed, and the azeas will be seeded with a pastureland seed <br />mixture. <br />In reference to the thickener underflow project, the reclamation work will involve removal of the pump, hosing and <br />piping, pump platform, support beams, powerline and poles, transformer, concrete pad, and grounding bed. The pump <br />will be removed from the pit, along with salvageable components, and then the remainder of the platform and support <br />beams will be dozed into the pit. The powerline and poles and transformer will be salvaged and the concrete pad will be <br />dozed into the pit. The Bounding bed will be disconnected and left in-place and covered during the backfilling and <br />grading of the surrounding azea. The azea then will be topsoiled and seeded in conjunction with the reclamation of the <br />entire portal/facilities area. <br />]8-Right Ventilation Shaft (TR04-44) <br />When the 18-Right Ventilation Shaft and emergency hoist equipment aze no longer required to support ongoing or futwe <br />mining operations, the associated surface facilities will be removed, the shaft will be plugged and sealed, and surface <br />disturbance areas will be reclaimed. The emergency hoist equipment will be removed and reused at another locale, <br />salvaged, or disposed of off-site. Concrete pads will be broken up and foundations will be demolished to at least 2 feet <br />.below grade, and the resulting concrete debris will be disposed of in the shaft opening. The shaft collar concrete will <br />also be broken up and disposed of into the shaft opening, leaving an open space for the concrete slab and backfill <br />material/shaft cuttings to be placed in the shaft void. A cement plug shall be placed in the bottom 15 feet of the shaft and <br />TR07-59 2.05 - 105.1 03/26/07 <br />