Laserfiche WebLink
AMERICAN <br />S O D A, L L P Ed Cooley <br />Environmental Health and <br />_ Safety Manager <br />2717 County Road 215 Direct Line (970) 285-0407 <br />Parachute, CO 81635 International Telephone +1 (970) 285-6500 <br />General Facsimile (970) 285-6393 <br />Friday June 4, 2004 <br />Elisabeth Evans <br />Director Technology Enforcement Program <br />U.S. Environmental Protection Agency <br />Region VIII <br />999 18"' Street, Suite 300 <br />Mail Code 8ENF-T <br />Denver, Colorado 80202-2466 <br />ENV.I 16.04 <br />Re: Well 20-14 (C03858-04599) <br />Dear Elisabeth: <br />During the plugging and abandonment procedures for well 20-14, American Soda has <br />had significant difficulty installing bridge plugs or cement baskets. ASLLP has had <br />success establishing a cement basket on the short string 7" casing at a depth of 1470'. <br />During milling operations on the long string 7" casing, the mill bit twisted off at a depth <br />of 1441'. <br />During subsequent fishing operations, ASLLP was unable to get the fishing tool past <br />1400' on the long string 7" casing. <br />On 6-3-2004, ASLLP performed a video inspection on both of the 7" casings on well 20- <br />14. The video inspection indicates a parted casing on both the long and short 7" <br />casings at a depth of 1394.6' The dissolution surface on well 20-14 is at 1442'. The <br />condition of the parted casing on the long string 7" casing prevents the insertion of a <br />bridge plug or a cement basket. <br />ASLLP proposes the following plugging procedure: <br />Run a 1 3/8" coil tubing as deep as possible into each 7" casing string. <br />Delivering a Crystal Clear Advantage <br />www.americansoda.com <br />