Laserfiche WebLink
:. <br />QA/QC Summary Report <br />Client: Cotter Corporation <br />Project: 7D-9 <br />Report Date: 04/28/05 <br />Work Order: 005040583 <br />Anatyte Result Unitr RL %REC Law Limit Nigh Limit RPD ~ RPDLimit Qua! <br />Method: SW6020 Batch: 7722 <br />Sample ID: 005040583-001AMSD4 Post Digestion Spike Dup 04/18/05 21:18 <br />Lead 0.078 mg/L 0.25 110 75 125 0 20 <br />Manganese 0.10 mg/L 0.25 112 75 125 0 20 <br />Mercury 0,0049 mg/L 0.025 98 75 125 0 20 <br />Nickel 0.064 mg/L 0.25 98.5 75 125 0 20 <br />Selenium 0.11 mg/L 0.025 97.7 75 125 2.2 20 <br />Silver 0.018 mg/L 0.12 36 75 125 0 20 S <br />Thallium 0.049 mg/L 2.5 96.5 75 125 0 20 <br />Uranium 0.33 mg/L 0.025 75 125 3.5 20 A <br />Zinc 0.053 mg/L 0.25 96.9 75 125 0 20 <br />-Matrix spike duplicate recoveries outside the acceptance criteria of 75 to 125 percent are censitlered matrix r elated, not system rela[etl, Reported valu es are within method <br />specifications. <br />Qualifiers: <br />RL -Anatyte reporting limit. <br />ND -Not detected at me reporting limit. <br />ENERGY LABORATOR/ES, /NC. • 2393 Sall Creek Highway (B2601J • P.O Box 3258 • Casper WYB2602 <br />TollFieeB8B.2350515 • 3072350515 • Fax3r77.2341639 • casper@energy/ab.ccm•wxnvenergy/ab.ccm <br />A -The analyte level was greater than four times the spike level. In <br />accordance with the method % recovery is not calculated. <br />S -Spike recovery outside of advisory limits. <br />