Laserfiche WebLink
fluid). The receivers will be lowered down the short 4'/2' tubing until the bottom <br />receiver is 20 feet above elevation of the highest source. The sources will be <br />detonated sequentially, lowest to highest. <br />NSA estimates this survey will take two days for on-site data collection. <br />After data collection is complete, NSA's personnel will return to Golden, <br />Colorado, to process the data, generate images, and prepare a final report. Data <br />processing and report preparation will be completed within 15 working days from <br />completion of data collection. <br />Recognizing that the goal of the project is to determine that this seismic <br />imaging technology is effective in mapping caverns produced by solution mining, <br />NSA will prepare a final report, including complete documentation of the test, <br />including study objectives and results, deployment and data collection, and data <br />processing and interpretation. <br />At completion of the final report, NSA will provide all field data, photographs, <br />survey data, and reporting, including images and supporting graphics, in <br />electronic format. <br />In addition, at the discretion of American Soda, NSA will make Tim Ross and a <br />senior geophysicist, Joe Descour, available to attend meetings with the <br />governing agencies for the purpose of discussing the seismic methods and <br />interpretations. <br />The sensor array that NSA will purchase from High Tech, Inc., on behalf of <br />American Soda will consist of a 10-channel cable, instrumented with 10 <br />hydrophones, attached at 20-ft intervals. This cable will have a total length of <br />2,600-ft lead. The specifications for this cable are listed in the table below. <br />Multi-Level Hydrophone <br />Cable 10 Channel - 20 foot spacing array <br />Total Cable Length - 2,600 feet <br />Stainless Steel top and bottom anchor (eye hook) <br />2 NK-27 connector on top-side <br />1 meter cable and anchor on bottom-side <br />Hydrophone Element: HTI- Element: -201 dB re: l V/microPa <br />02-DHPC 8.9 VBar <br /> Preamplifier Gain 20dB <br /> Sensitivity: -183 dB re: 1 V/microPa w/200 ohm termination resistor <br /> Power 15 -40 VDC <br /> Hydrophone elements are potted in a shielded protective aluminum can <br /> Dimensions: 2.25" L x 0.625" OD <br /> OPERATING TEMP. = 0 - 200 degrees C <br /> MAX. PRESS. = 10,000 PSI <br />Type of Cable Water-blocked, Double-extruded Polyurethane jacket <br /> Hydtophone PODS OD=1.0" are over-molded in-line to cable <br /> Cable -0.315" OD (16.3mm) <br /> 1,80016. strength member (Kevlaz) <br /> Max o eratin de the 6,000 meters <br />