Laserfiche WebLink
<br />COLORADO DEPARTrtENT OF HEALTH, Water Quality Control Division <br />Rationale - Page 2. Permit No. CO-0037605 <br />MONITORING SUPRIARY <br />No discharge has ever been reported from this facility. <br />APPLICABLE RULES AND REGULATIONS: <br />Table 1 below shows State Effluent Standards (SES), Federal Best Practicable <br />Control Technology (BPT), Federal Beat Available Technology Economically <br />Achievable (BAT) aad State Water Quality Standards (WQS) applicable to this <br />facility. <br />Table 1 <br />Parameter SES BPT BAT WQS <br />pH, s.u. a/ 6.0 - 9.0 6.0 - 9.0 N/A 6.5 - 9.0 <br />011 and Grease, mg/1 al 10.0 NIA N/A N/A <br />Total Suspended SoLida, mg/1 30/45 dl 35170 b/ N/A NIA <br />Total Iron, mg/1 N/A 3.5/7.0 b/ 3.5/7.0 N/A <br />Settleable Solids, ml/1 c/ N/A N/A 0.5 N/A <br />a/ This parameter applicable at all times <br />b/ This limitation applicable to discharges during periods of no precipitation <br />c/ Thla parameter applicable to discharges during periods of precipitation less <br />than or equal to the 10-year, 24-hour event for this facility <br />d/ See discussion section <br />