My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2006-07-20_REVISION - M1988112
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1988112
>
2006-07-20_REVISION - M1988112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 5:36:10 PM
Creation date
11/22/2007 12:05:44 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Revision
Doc Date
7/20/2006
Doc Name
Exhibits
From
Battle Mountain
To
DMG
Type & Sequence
AM2
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the design flow under non-pressurized, partially-full pipe flow conditions. Table G.2- <br />2 lists the normal flow depth under partially-full pipe flow conditions over the range <br /> <br />of pipeline slopes that will exist along [he pipeline profile. <br />Table G.2-2 Normal Flow Depth, 8-inch SDR 17 (7.611 ID) at 550 gpm <br />Pipe Slope Normal Flow Depth <br />ftlft Inch <br />0.010 5.60 <br />0.015 4.82 <br />0.020 4.38 <br />0.025 4.09 <br />0.030 3.87 <br />0.035 3.70 <br />0.040 3.56 <br />0.045 3.44 <br />0.050 3.34 <br />0.055 3.25 <br />0.060 3.18 <br />0.065 3. ] 1 <br />0.070 3.04 <br />0.075 2.99 <br />0.080 2.93 <br />0.085 2.89 <br />0.090 2.84 <br />G.2.4 Construction QA/QC Plan <br />The following is a general summary of proposed construction QA/QC procedures for <br />pond and pipeline construction. All work shall conform to applicable Federal, State, <br />and County regulations. Testing procedures will conform to applicable ASTM <br />standards, as documented in the edition of standards in force at the start of work <br />(ASTM, 2005 or future annual edition). <br />On-site inspection of construction activities and quality assurance (QA) testing will <br />be conducted by a qualified Field Engineer, at key points during construction. The <br />Field Engineer will be appointed by BMRI and will be independent representatives of <br />BMRI. The inspection and QA testing conducted by the Field Engineer will be <br />performed under the direct supervision of a Professional Engineer registered in the <br />State of Colorado (Professional Engineer). <br />Battle Mountain Resources, Inc. G-g Telesto Solutions, Inc. <br />P1ROjxLS~212-NewmontlSSnLnis)~SavL~isNe,Nit MlenGOent- West Pi~Mavagemenl~PetmitNnev~ment_v3.doc July 2006 <br />
The URL can be used to link to this page
Your browser does not support the video tag.