Laserfiche WebLink
DMG Concern <br />III.B.10. CEC should present updated data on conductivity, iron and pH for <br />all wells in which these parameters are analyzed. The data should <br />be presented in a manner that enables the Division to evaluate <br />trends )e.g. graphs or a table showing annual means, maximums <br />and minimums for each parameter). According to the ground water <br />monitoring plan, the following wells are sampled for the referenced <br />parameters: 5MN, OK, TR-4, TR-7A, 81-01, 259, 9MN, AVF-3, AVF-5, <br />AVF-6, #9 BF-5. <br />CEC Response <br />Please refer to previous item. <br />DMG Concern <br />III.C. Subsidence Control Plan; one reference to Well 259 as depicted on <br />subsidence Monitoring Map 31 was made on revised page 2.05.6(6)-22. <br />The most current Map 31 the Division has is dated October 1991. Well 259 <br />is not identified on this map. please, either revise the map reference to a <br />map the well is noted on or revise Map 31 to locate well 259. <br />CEC Response <br />The revised map was included with the previous submittal. <br />