My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REV96134
DRMS
>
Back File Migration
>
Revision
>
REV96134
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 3:20:55 AM
Creation date
11/21/2007 11:56:18 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1999021
IBM Index Class Name
Revision
Doc Name
TECHNICAL SPECIFICATIONS FOR THE CONSTRUCTION OF STEGNER FARMS PIT SLURRY WALL LARIMER CNTY COLO
Type & Sequence
TR1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Known utilities and structures adjacent to or encountered in the work are shown on the <br />Drawings. The locations shown are taken from existing records and the best information <br />available from existing utility plans, however, it is expected that there may be some <br />discrepancies and omissions in the locations and quantities of utilities and structures <br />shown. Those shown are for the convenience of the Contractor only, and no <br />responsibility is assumed by the Engineer for their accuracy or completeness. <br />PART 3 -CONTRACTOR'S RESPONSIBILITY FOR UTILITY PROPERTIES AND SERVICE <br />3.01 GENERAL <br />A. Where the Contractor's operations could cause damage or inconvenience [o railway, telegraph, <br />telephone, television, oil, gas, electricity, water, sewer, or imgation systems, the operations shall <br />be suspended until all arrangements necessary far the protection of these utilities and services <br />have been made by the Contractor. <br />B. Notify all utility offices which are affected by the construction operation at least ~38 hours in <br />advance. Under no circumstances expose any utility without first obtaining permission from the <br />appropriate agency. Once permission has been granted, locate, expose, and provide temporary <br />support for all existing underground utilities. <br />C. The Contractor shall protect all utility poles from damage. If interfering power poles, telephone <br />poles, guy wires, or anchors are encountered, notify [he Engineer and the appropriate utility <br />company at least 48 hours in advance of construction operations to permit the necessary <br />arrangements for protection or relocation of [he interfering structure. <br />D. The Contractor shall be solely and directly responsible to the Owner and operators of such <br />properties for any damage, injury, expense, loss, inconvenience, delay, suits, actions, or claims of <br />any character brought because of any injuries or damage which may result from the construction <br />operations under this Contract. <br />E. The Engineer shall not be responsible to the Contractor for damages as a result of the Contractor's <br />failure to protect utilities encountered in the work. <br />F. If the Contractor while performing the Contract discovers utility facilities not identified in the <br />Drawings or Specifications, he shall immediately notify the utility, and the Engineer in writing. <br />G. N the even[ of interruption to domestic water, sewer, storm drain, or other utility services as a <br />result of accidental breakage due to conswction operations, promptly notify the proper authority. <br />Cooperate with said authority in the restoration of service as promptly as possible and bear all <br />costs of repair. In no case shall interruption of any water or utility service be allowed [o exist <br />outside working hours unless prior approval is granted. <br />H. The Contractor shall replace, at his own expense, any and all other existing utilities or s[ructtues <br />removed or damaged during conswction, unless otherwise provided for in these Contract <br />Documents or ordered by the Engineer. <br />01/99 Section 01 l60 -Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.