My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1992-04-01_REVISION - M1988112
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1988112
>
1992-04-01_REVISION - M1988112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2021 3:50:24 PM
Creation date
11/21/2007 11:05:44 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Revision
Doc Date
4/1/1992
Doc Name
QUALITY ASSURANCE QUALITY CONTROL PROTOCOLS FOR THE COLLECTION OF SURFACE & GROUND WATER QUALITY
Type & Sequence
TR6
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
~ fly/~ <br />' Western Atlas <br />International <br />o. c~a., <br />CORE LABOgATORIES <br />Ir I r I F _,. <br />ANALYTICAL CHEMISTRY DIVISION QUALITY ASSURANCE MANUAL <br />' SOP NO. REVISION N0. EFFECTIVE OATE PAOE <br />HC-QAC-02 0 1 /06/92 80 of 104 <br />' <br /> when sample extractions for semivolatiles, pesticides or herbicides are <br /> performed. <br />' <br /> Extraction Blanks <br /> Extraction blanks must be analyzed every time samples are extracted. This <br /> extraction blank must be the same matrix type as the samples being <br /> processed. Purified silica sand may be used as an extraction material for <br />t soil/sludge matrices. <br />' Initial/Continuing Calibration Verification <br /> An initial calibration must be performed every time that a GC column is <br />' replaced, the mass spectrometer source is cleaned or repAired, or any time <br />major modifications are made to the instrument system. Daily calibrations are <br /> required to verify proper equipment operation prior to sample analysis. If the <br />' daily calibration verification does not meet method-spe lfied acceptance <br />criteria, a new initial calibration must be performed. Acceptance criteria for <br /> intial and continuing calibration verifications are provided +n the applicable <br /> analytical method. <br /> Svstem Performance Standard <br /> GC/MS system performance check standards (tuning compounds) must be <br /> analyzed daily for volatile and semivolatile analyses. <br />1 S <br />R <br />i <br />l <br /> urrogate <br />ecover <br />es <br />i <br /> Surrogates are required for volatile, semivolatile, pesticid@, and herbicide' <br /> analyses. <br /> Surrogate recoveries must meet the method-specified QC limits. When <br /> surrogate recoveries do not meet the method-specified criteria, that sample <br /> must be reanalyzed. If surrogate recoveries on the reanalysis (still do not meet <br />' method-specified Limits, a probable matrix interference problerln exists, and the <br /> sample data should be qualified as estimated. Do not repdrt these results, <br /> until the data has been reviewed and approved by the laboratory section i <br />' supervisor or the QA/QC coordinator. <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.